Comparison of Algorithms for Haptic Interaction With Isosurfaces Extracted From Volumetric Datasets.

J Comput Inf Sci Eng

e-mail:  2039 Engineering Research Facility, University of Illinois at Chicago, 842 West Taylor Street, Chicago, IL 60607.

Published: June 2012

Combinations of graphics and haptics libraries are used in medical simulations for simultaneous visualization and tactile interaction with complex 3D anatomy models. The minimum frame rate of 1 kHz for haptics rendering makes it a nontrivial problem when dealing with complex and highly detailed polygonal models. Multiple haptics algorithms based on polygonal mesh rendering, volume haptics, and intermediate representation are evaluated in terms of their servoloop rendering time, client thread rendering time, and quality of force feedback. Algorithms include OpenHaptics' Feedback Buffer and Depth Buffer, GodObject and Ruspini renderers in h3d, chai3d implementation in h3d, ScalarSurfaceFriction mode in Volume Haptics ToolKit (vhtk), and the authors' intermediate representation algorithm based on volumetric data. The latter, in combination with surface graphics visualization, is found to deliver the best rendering time, to detect all collisions and to provide correct haptic feedback where other algorithms fail.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994752PMC
http://dx.doi.org/10.1115/1.4006465DOI Listing

Publication Analysis

Top Keywords

rendering time
12
volume haptics
8
intermediate representation
8
feedback algorithms
8
haptics
5
rendering
5
comparison algorithms
4
algorithms haptic
4
haptic interaction
4
interaction isosurfaces
4

Similar Publications

Burying poultry carcasses on farms as a disposal option in crisis situations: learnings and perspectives from a field study during an avian influenza epizootic in France.

Poult Sci

January 2025

Ploufragan-Plouzané-Niort Laboratory, Epidemiology Health and Welfare Unit, French Agency for Food, Environmental and Occupational Health and Safety (ANSES), BP53 22440 Ploufragan, France. Electronic address:

Appropriate disposal of dead farming animals is required to guarantee effective disease control while protecting the environment. In crisis situations, alternatives to rendering can be used, including on-farm burial. The objectives of this study were to: (i) describe the burial and monitoring protocols used on poultry farms in France in response to major avian influenza outbreaks; (ii) assess the effectiveness of the burial protocol, in terms of both technical and biosecurity aspects, and microbiological, physical and chemical changes of the buried materials and the environment over time; (iii) provide recommendations for future burial and follow-up protocols.

View Article and Find Full Text PDF

Computed tomography dataset virtual dissection for sternal re-entry in congenital cardiac surgery.

Indian J Thorac Cardiovasc Surg

February 2025

Department of Paediatric and Congenital Heart Surgery, Kokilaben Dhirubhai Ambani Hospital and Medical Research Institute, Rao Saheb, Achutrao Patwardhan Marg, Four Bungalows, Andheri West, Mumbai, Maharashtra 400053 India.

Unlabelled: In congenital heart surgery, redo-sternotomies are very common. In most cases, sternal re-entry is achieved without serious complications. However, sometimes elective institution of peripheral cardiopulmonary bypass is needed for safe sternotomy, albeit with a long cardio-pulmonary bypass time.

View Article and Find Full Text PDF

Viral hepatitis is a major public health challenge. Hepatitis C Virus (HCV) infection causes the progressive liver damage. A surprisingly high number of individuals tested positive for HCV infection during the Unnao Human Immunodeficiency Virus (HIV) outbreak investigation in 2017-2018 (more than 90% of the people living with HIV were from the Premganj township and Chakmeerapur village of the district in the northern State of Uttar Pradesh).

View Article and Find Full Text PDF

Background: This study aimed to quantify radiation doses during navigational bronchoscopy procedures, comparing them with reported cohorts and evaluating the LungVision (Body Vision Medical Inc.) system's efficacy in dose reduction.

Methods: This retrospective observational study included 52 consecutive navigational bronchoscopy cases, categorized into 4 imaging groups based on the C-arm: Cios Spin (Siemens Healthineers), or OEC 9900 (GE HealthCare); and the 3D tomographic imaging algorithm: Cios Spin's onboard imaging, or LungVision's AI-driven imaging.

View Article and Find Full Text PDF

Traditional polymer systems often rely on toxic initiators or catalysts for cross-linking, posing significant safety risks. For bone tissue engineering, another issue is that the scaffolds often take a longer time to degrade, inconsistent with bone formation pace. Here, we developed an enzyme-responsive biodegradable poly(propylene fumarate) (PPF) and polycaprolactone (PCL) polyphosphoester (PPE) dendrimer cross-linked utilizing click chemistry (EnzDeg-click-PFCLPE scaffold) for enhanced biocompatibility and degradation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!