A rapid and sensitive ultra high performance liquid chromatography method with diode array detection was developed for the fingerprint analysis and simultaneous determination of seven active compounds in Xiaoyanlidan (XYLD) tablets. The chromatographic separations were obtained on an Agilent Eclipse plus C18 column (50 × 2.1 mm id, 1.8 μm) using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. Within 63 min, 36 peaks could be selected as the common peaks for fingerprint analysis to evaluate the similarities among several samples of XYLD tablets collected from different manufacturers. In quantitative analysis, seven compounds showed good regression (R > 0.9990) within test ranges and the recovery of the method was within the range of 95.9-104.3%. The method was successfully applied to the simultaneous determination of seven compounds in six batches of XYLD tablets. These results demonstrate that the combination of chromatographic fingerprint analysis and simultaneous multi-ingredient quantification using the ultra high performance liquid chromatography method with diode array detection offers a rapid, efficient, and reliable approach for quality evaluation of XYLD tablets.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201400362DOI Listing

Publication Analysis

Top Keywords

fingerprint analysis
16
xyld tablets
16
ultra high
12
high performance
12
performance liquid
12
liquid chromatography
12
diode array
12
array detection
12
quantitative analysis
8
quality evaluation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!