Objective: To compare the biomechanical properties of four types of internal fixation (proximal femoral nail [PFN], dynamic hip screw [DHS], dynamic condylar screw [DCS], and proximal femoral locking plate [PFLP]) for different types of subtrochanteric fractures.
Methods: Thirty-two antiseptic femurs were randomly divided into four groups. After internal fixation had been implanted, different types of subtrochanteric fracture models were produced and each tested under vertical, torsional and vertical damage loads.
Results: The stiffness ratio of PFN in each fracture model and failure load were the highest in the four groups; however, the torsional stiffness ratio was the lowest. Tension strain ratios of DHS and DCS on the lateral side became compression strain ratios with restoration of the medial fragment. The stiffness ratio of DHS was lower than PFLP in each fracture model, torsional stiffness ratio was the highest in fracture models II to V and the failure load was lower only than PFN. The stiffness ratio and failure load of DCS were both the lowest, torsional stiffness ratio was similar to PFLP's in fracture models II to V. The stiffness ratio of PFLP was only lower than PFN's in each fracture model, but the failure load was lower than DHS's.
Conclusion: Four types of internal fixation achieve better stabilities for type I subtrochanteric fractures. PFN and PFLP produce reliable stability in type IIIA subtrochanteric fractures. If the medial buttress is restored, DCS can be considered. For type IV subtrochanteric fractures, only PFN provides stable fixation. PFLP is suitable for comminuted fractures with large fragments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6583598 | PMC |
http://dx.doi.org/10.1111/os.12109 | DOI Listing |
Dig Liver Dis
January 2025
State Key Laboratory of Holistic Integrative Management of Gastrointestinal Cancers, National Clinical Research Center for Digestive Diseases, Xijing Hospital, The Air Force Military Medical University, Xi'an, 710032, Shaanxi, China. Electronic address:
Background: Positivity for anti-gp210 and anti-centromeric antibodies (ACA) in patients with primary biliary cholangitis (PBC) have been associated with the progression of liver failure and portal hypertension (PH), respectively. The value of combining risk autoantibody assessments with prognostic scoring systems in improving risk assessment in patients with PBC remains unclear.
Aims: To investigate the prognostic significance of various combinations of anti-gp210 and ACA statuses and their enhancing the prognostic utility on the GLOBE scoring system.
Ultrasound Med Biol
January 2025
Echosens, Paris, France.
Objective: Although FibroScan (FS), based on Vibration-Controlled Transient Elastography (VCTE), is a widely used non-invasive device for assessing liver fibrosis and steatosis, its current standard-VCTE examination remains timely and difficult on patients with obesity. The Guided-VCTE examination uses continuous shear waves to locate the liver by providing a real-time predictive indicator for shear wave propagation and uses shear wave maps averaging to increase the signal-to-noise ratio in difficult to assess patients. We aimed to evaluate the effectiveness of the new indicator, as well as compare examination times and success rates with both standard-VCTE and Guided-VCTE examinations.
View Article and Find Full Text PDFPediatr Nephrol
January 2025
Nephrology, Children's National Hospital, 111 Michigan Avenue NW, Washington, DC, 20010, USA.
Background: Obesity and metabolic syndrome (MS) accelerate arterial stiffening, increasing cardiovascular (CV) risk after transplant. BMI is limited by inability to differentiate muscle, fat mass, and fat distribution patterns. The aim of this study was to identify the best anthropometric measure to detect arterial stiffness as assessed by pulse wave velocity (PWV) in a racially diverse pediatric transplant population.
View Article and Find Full Text PDFArterial compliance (AC) is an important cardiovascular parameter characterizing mechanical properties of arteries. AC is significantly influenced by arterial wall structure and vasomotion, and it markedly influences cardiac load. A new method, based on a two-element Windkessel model, has been recently proposed for estimating AC as the ratio of the time constant T of the diastolic blood pressure decay and peripheral vascular resistance derived from clinically available stroke volume measurements and selected peripheral blood pressure parameters which are less prone to peripheral distortions.
View Article and Find Full Text PDFACS Mater Au
January 2025
Christian Doppler Laboratory for Soft Structures for Vibration Isolation and Impact Protection (ADAPT), School of Education, STEM Education, Johannes Kepler University Linz, 4040 Linz, Austria.
Soft materials play a pivotal role in the efficacy of stretchable electronics and soft robotics, and the interface between the soft devices and rigid counterparts is especially crucial to the overall performance. Herein, we develop polyimide-polydimethylsiloxane (PI-PDMS) copolymers that, in various ratios, combine on a molecular level to give a series of chemically similar materials with an extremely wide Young's modulus range starting from soft 2 MPa and transitioning to rigid polymers with up to 1500 MPa. Of particular significance is the copolymers' capacity to prepare seamless stiffness gradients, as evidenced by strain distribution analyses of gradient materials, due to them being unified on a molecular level.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!