A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid determination of corticosterone in mouse plasma by ultra fast liquid chromatography-tandem mass spectrometry. | LitMetric

Rapid determination of corticosterone in mouse plasma by ultra fast liquid chromatography-tandem mass spectrometry.

Biomed Chromatogr

College of Pharmacy, Nanjing University of Chinese Medicine, Nanjing, China; School of Applied Science, Temasek Polytechnic, Singapore.

Published: December 2014

Major depressive disorder is a severe, life-threatening and highly prevalent psychiatric disorder. A high percentage of people suffering from depression are characterized by hyperactivity of the hypothalamic-pituitary-adrenal axis, resulting in plasma glucocorticoid (cortisol in human and corticosterone in rodent) elevations. Glucocorticoid is a critical molecule in the onset of pathology of depression. A simple, highly sensitive and specific method based on ultra-fast liquid chromatography-tandem mass spectrometry method has been developed for the quantitation of corticosterone in mouse plasma for the first time, which provides technical support for the high-throughput measurement for clinical determination of corticosterone in biological samples. Samples were spiked with methanol to precipitate the protein, and then chromatographed on an Agilent Zorbax Eclipse Plus C18 (100 × 2.1 mm,1.8 µm) column by linear gradient elution with methanol and 0.1% formic acid as the mobile phase within 5 min. The detection of corticosterone was performed on ultra-fast liquid chromatography-triple quadrupole tandem mass spectrometry in the positive ion. The ions [M + H](+) m/z 347.2 → m/z 311.1 for corticosterone and [M + H](+) m/z 363.2 → m/z 327.2 for hydrocortisone (internal standard) were used for quantitative determination. The lower quantification limit for corticosterone was 1 ng/mL. The validated method was successfully applied to the quantitation of corticosterone in mouse plasma.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.3232DOI Listing

Publication Analysis

Top Keywords

corticosterone mouse
12
mouse plasma
12
mass spectrometry
12
corticosterone
8
determination corticosterone
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
ultra-fast liquid
8
quantitation corticosterone
8
[m + h]+ m/z
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!