Background: Alveolar echinococcosis, caused by the metacestode larval stage of Echinococcus multilocularis, is a zoonosis of public health significance and is highly prevalent in northwest China. To effectively monitor its transmission, we developed a new rapid and cheap diagnostic assay, based on loop-mediated isothermal amplification (LAMP), to identify canine definitive hosts infected with E. multilocularis.

Methods: The primers used in the LAMP assay were based on the mitochondrial nad5 gene of E. multilocularis and were designed using Primer Explorer V4 software. The developed LAMP assay was compared with a conventional PCR assay, using DNA extracted from the feces of dogs experimentally infected with E. multilocularis, on 189 dog fecal samples collected from three E. multilocularis-endemic regions in Qinghai province, the People's Republic of China, and 30 negative control copro-samples from dogs from an area in Gansu province that had been subjected to an intensive de-worming program. Light microscopy was also used to examine the experimentally obtained and field collected dog copro-samples for the presence of E. multilocularis eggs.

Results: The E. multilocularis-positivity rates obtained for the field-collected fecal samples were 16.4% and 5.3% by the LAMP and PCR assays, respectively, and all samples obtained from the control dogs were negative. The LAMP assay was able to detect E. multilocularis DNA in the feces of experimentally infected dogs at 12 days post-infection, whereas the PCR assay was positive on the 17th day and eggs were first detectable by light microscopy at day 44 post-challenge.

Conclusion: The earlier specific detection of an E. multilocularis infection in dog copro-samples indicates that the LAMP assay we developed is a realistic alternative method for the field surveillance of canines in echinococcosis-endemic areas.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4081488PMC
http://dx.doi.org/10.1186/1756-3305-7-254DOI Listing

Publication Analysis

Top Keywords

lamp assay
20
loop-mediated isothermal
8
isothermal amplification
8
amplification lamp
8
assay
8
echinococcus multilocularis
8
canine definitive
8
definitive hosts
8
assay based
8
pcr assay
8

Similar Publications

Development of a portable multi-step microfluidic device for point-of-care nucleic acid diagnostics.

Anal Chim Acta

January 2025

State Key Laboratory of Microbial Technology, Microbial Technology Institute, Shandong University, Qingdao, Shandong, 266237, China. Electronic address:

Background: The COVID-19 pandemic has significantly affected global health, economies, and societies, and highlighted the urgent need for rapid, sensitive, affordable, and portable diagnostic devices for respiratory diseases, especially in areas with limited resources. In recent years, there has been rapid development in integrated equipments using microfluidic chips and biochemical detection technologies. However, these devices are expensive and complex to operate, showing limited feasibility for in point of care tests (PoCTs).

View Article and Find Full Text PDF

Loop-mediated isothermal amplification (LAMP) is a detection method widely used in pathogen detection and clinical diagnosis. Nevertheless, it is highly constrained by thermal stability, catalytic activity, and resistance to inhibitors of Bst DNA polymerase. In this study, a novel DNA polymerase was characterized from Clostridium thermocellum, exhibiting potential in LAMP detection.

View Article and Find Full Text PDF

Milk is commonly screened both for indicators of animal disease and health, but also for foodborne hazards. Included in these analyses is the detection of , that can produce an enterotoxin, causing staphylococcal food poisoning (SFP), which often leads to sudden onset of significant gastrointestinal symptoms in humans. Epidemiological data on SFP are limited, particularly in low- and middle-income countries.

View Article and Find Full Text PDF

Human Papillomavirus (HPV) infection is a significant global health concern linked to various cancers, particularly cervical cancer. Timely and accurate detection of HPV is crucial for effective management and prevention strategies. Traditional laboratory-based HPV testing methods often suffer from limitations such as long turnaround times, restricted accessibility, and the need for trained personnel, especially in resource-limited settings.

View Article and Find Full Text PDF
Article Synopsis
  • Sexual assault investigations require skilled forensic methods to collect biological evidence, focusing on male-specific materials.
  • A new LAMP technique was developed to effectively detect male DNA and was validated according to established guidelines.
  • When tested against traditional methods, the LAMP assay showed impressive efficiency, suggesting it could be a valuable tool in forensic casework for male DNA detection, pending further research.
View Article and Find Full Text PDF