Background: As for the surgical treatment of the rotator cuff tears, the subscapularis tendon tears have recently received much attention for the mini-open or arthroscopic repair. The results of surgical repair for the subscapularis tendon tear are satisfactory, but the range of external rotation is reported to be restricted after the repair. The purpose of this study was to evaluate the range of glenohumeral joint motion after repairs of various sizes of subscapularis tendon tears.

Methods: Using eight fresh frozen human cadaveric shoulders (mean age at death, 81.5 years), three sizes of subscapularis tendon tear (small, medium, and large) were made and then repaired. With the scapula fixed to the wooden jig, the end-range of glenohumeral motion was measured with passive movement applied through 1.0-Nm torque in the directions of scapular elevation, flexion, abduction, extension, horizontal abduction, and horizontal adduction. The passive end-ranges of external and internal rotation in various positions with rotational torque of 1.0 Nm were also measured. Differences in the ranges among the three type tears were analyzed.

Results: As tear size increased, range of glenohumeral motion in horizontal abduction after repair decreased gradually and was significantly decreased with the large size tear (P < 0.01). The end-range of external rotation decreased progressively with increasing tear size in every glenohumeral position. The prominent decrease in external rotation (around 40° reduction from intact shoulders) was observed in shoulders after repair of large size tear at 30° to 60° of scapular elevation and abduction.

Conclusions: As the size of the subscapularis tendon tear increased, the passive ranges of horizontal abduction and external rotation of the glenohumeral joint after repair decreased significantly. In shoulders with a subscapularis tendon tear, it is necessary to consider the reduction of external rotation depending on tear size.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4035761PMC
http://dx.doi.org/10.1186/1749-799X-9-41DOI Listing

Publication Analysis

Top Keywords

subscapularis tendon
20
glenohumeral joint
8
joint motion
8
tendon tear
8
range glenohumeral
8
sizes subscapularis
8
glenohumeral motion
8
horizontal abduction
8
subscapularis
5
tendon
5

Similar Publications

Background: Muscle atrophy after the rupture of a rotator cuff (RC) tendon is a major factor that increases the risk of secondary complications and re-rupture. Metformin, a type 2 diabetes treatment, can be used to modulate intracellular signaling pathways that promote muscle growth. This study aimed to verify whether systemic metformin administration could prevent supraspinatus (SS) atrophy after RC rupture in a rat model.

View Article and Find Full Text PDF

Sling is Not-Inferior to Brace Immobilization Following Arthroscopic Rotator Cuff Repair: A Randomized Controlled Trial.

Arthroscopy

December 2024

Orthopaedic and Traumatology Unit, Ospedale Regionale di Lugano, EOC, 6900, Lugano, Switzerland; Faculty of Biomedical Sciences, Università della Svizzera Italiana, Via Buffi 13, 6900, Lugano, Switzerland.

Purpose: The aim of this study was to compare the safety and efficacy of immobilizing the upper limb with a brace versus a less-constrained sling in the rehabilitation after arthroscopic rotator cuff repair (ARCR), by documenting clinical and radiological results.

Methods: ARCR was performed in 110 patients (54.9±8.

View Article and Find Full Text PDF

The Transverse Humeral Ligament: An Anatomical Narrative Review.

Clin Anat

December 2024

Division of Gross and Clinical Anatomy, Department of Anatomy, Kurume University School of Medicine, Fukuoka, Japan.

Shoulder pain often involves the tendon of the long head of the biceps brachii (LHBT) and the transverse humeral ligament (THL). Traditionally, the THL is considered a ligament that prevents the LHBT from dislocating, but recent studies suggest that it may be part of the subscapularis tendon. This review evaluates the nature of the THL and its overlying structures.

View Article and Find Full Text PDF

Purpose: Improve the accuracy of one-stage object detection by modifying the YOLOv7 with Convolutional Block Attention Module (CBAM), known as YOLOv7-CBAM, which can automatically identify torn or intact rotator cuff tendon to assist physicians in diagnosing rotator cuff lesions through ultrasound.

Methods: Between 2020 and 2021, patients who experienced shoulder pain for over 3 months and had both ultrasound and MRI examinations were categorized into torn and intact group. To ensure balanced training, we included the same number of patients on both groups.

View Article and Find Full Text PDF

Background: Failure after rotator cuff repair is typically due to a loss of integrity of the bone-tendon interface. The BioWick anchor (Zimmer-Biomet) is an interpositional scaffold-anchor that was developed to improve tendon-bone healing. The purpose of this study was to determine the clinical efficacy of this novel anchor compared with a standard anchor with respect to retear rates and patient outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!