A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability analysis of two methods for measuring active enamel demineralization: An in vitro study. | LitMetric

Reliability analysis of two methods for measuring active enamel demineralization: An in vitro study.

Eur J Dent

Department of Pediatric Dentistry and Orthodontics, Dental School, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.

Published: April 2013

Objective: The aim was to evaluate the intra- and inter-examiner reliability of two methods, namely, digital caliper [DC] and computerized image analysis software (Image Tool [IT] version 4.1) for measuring the area of an active enamel demineralization lesion. The effect on that measurement of a window that delimits the lesion was also assessed.

Materials And Methods: Thirty-eight circular artificial enamel demineralization lesions (r = 2 mm) were produced on bovine teeth in vitro, which were then measured three times by three examiners, with and without the presence of a window delimiting the area to be measured. The data were analyzed by the intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and by the Altman and Bland analysis.

Results: The intra-examiner correlation using the IT method showed excellent reproducibility (mean ICC values 0.922-0.970 with the delimiting window and 0.915-0.990 without the window). However, the intra-examiner correlation using the DC method showed comparatively less reproducibility in the measurements (mean ICC values 0.458-0.648 with the delimiting window and 0.378-0.665 without the window). The inter-examiner correlations showed very good reproducibility of the measurements regardless of the presence or absence of the window for both the DC method (0.811-0.846) and IT method (0.953-0.994). However, the latter method showed less variability within the measurements.

Conclusion: However, statistically no significant difference was found between both methodologies. Nevertheless, computerized image analysis with the Image Tool software demonstrated higher intra- and inter-examiner reliability than the digital caliper method, in estimating the area of the enamel demineralization lesion, regardless of the delimiting window.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4023199PMC
http://dx.doi.org/10.4103/1305-7456.110157DOI Listing

Publication Analysis

Top Keywords

enamel demineralization
16
delimiting window
12
active enamel
8
intra- inter-examiner
8
inter-examiner reliability
8
digital caliper
8
computerized image
8
image analysis
8
image tool
8
demineralization lesion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!