An 8-channel E-band heterodyne radiometer system (74-86 GHz) is designed, characterized, and calibrated to measure the radial electron temperature profile by measuring Electron Cyclotron Emission spectrum at SST-1 Tokamak. The developed radiometer has a noise equivalent temperature of 1 eV and sensitivity of 5 × 10(9) V/W. In order to precisely measure the absolute value of electron temperature, a calibration measurement of the radiometer system is performed using hot-cold Dicke switch method, which confirms the system linearity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4873197 | DOI Listing |
Br J Anaesth
December 2024
INI-CRCT Network, Nancy, France; Université Paris Cité, AP-HP, Hôpital Lariboisière, DMU PARABOL, Service d'Anesthésie-réanimation-CTB, Paris, France; UMR-942 "MASCOT", Inserm, Paris, France.
Strong recommendations on how to manage renin-angiotensin system inhibitors, including angiotensin-converting enzyme inhibitors and angiotensin receptor blockers, before surgery are lacking because of a lack of evidence, which is mostly limited to data from observational studies. The STOP-or-NOT trial was a large multicentre randomised trial designed to determine whether chronic renin-angiotensin system inhibitors should be continued or discontinued before major noncardiac surgery. As principal investigators of the STOP-or-NOT trial, we discuss the trial's results and how they contribute to the existing literature on management of renin-angiotensin system inhibitors before surgery.
View Article and Find Full Text PDFExp Astron (Dordr)
January 2025
Institute of Space Sciences and Astronomy, University of Malta, Msida, Malta.
We detail the REACH radiometric system designed to enable measurements of the 21-cm neutral hydrogen line. Included is the radiometer architecture and end-to-end system simulations as well as a discussion of the challenges intrinsic to highly-calibratable system development. Following this, we share laboratory results based on the calculation of noise wave parameters utilising an over-constrained least squares approach.
View Article and Find Full Text PDFAm J Perinatol
January 2025
Pediatrics, Duke University Health System, Durham, United States.
Objective: To characterize the cerebrospinal fluid (CSF) of infants with stroke and compare those findings to the CSF of infants with bacterial meningitis and neither condition in the first 14 postnatal days.
Study Design: Cohort study of 30,092 infants who received a lumbar puncture in the first 14 postnatal days discharged from >300 neonatal intensive care units from 1997-2020. CSF parameters were compared between infants with stroke and bacterial meningitis using non-parametric hypothesis testing and quantile regression.
Sensors (Basel)
December 2024
CommSensLab-UPC, Universitat Politècnica de Catalunya-BarcelonaTech, 08034 Barcelona, Spain.
Interferometric radiometers operating at L-band, such as ESA's SMOS mission, enable crucial Earth observations providing high-resolution measurements of soil moisture, ocean salinity, and other geophysical parameters. However, the increasing electromagnetic spectrum utilization has led to significant Radio Frequency Interference (RFI) challenges, particularly critical given the sensors' fine temperature resolution requirements of less than 1 K. This work presents the hardware implementation of an advanced RFI detection and mitigation algorithm specifically designed for interferometric radiometers, targeting future L-band missions.
View Article and Find Full Text PDFActa Anaesthesiol Scand
February 2025
Department of Anaesthesiology, Centre for Cancer and Organ Diseases, Rigshospitalet, Copenhagen, Denmark.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!