Point-of-care microdevices for blood plasma analysis in viral infectious diseases.

Ann Biomed Eng

Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Pennsylvania State University, N-238 Millennium Science Complex, University Park, PA, 16802, USA.

Published: November 2014

Each year, outbreaks of viral infections cause illness, disability, death, and economic loss. As learned from past incidents, the detrimental impact grows exponentially without effective quarantine. Therefore, rapid on-site detection and analysis are highly desired. In addition, for high-risk areas of viral contamination, close monitoring should be provided during the potential disease incubation period. As the epidemic progresses, a response protocol needs tobe rapidly implemented and the virus evolution fully tracked. For these scenarios, point-of-care microdevices can provide sensitive, accurate, rapid and low-cost analysis for a large population, especially in handling complex patient samples, such as blood, urine and saliva. Blood plasma can be considered as a mine of information containing sources and clues of biomarkers, including nucleic acids, immunoglobulin and other proteins, as well as pathogens for clinical diagnosis. However, blood plasma is also the most complicated body fluid. For targeted plasma biomarker detection or untargeted plasma biomarker discovery, the challenges can be as difficult as identifying a needle in a haystack. A useful platform must not only pursue single performance characteristics, but also excel at multiple performance parameters, such as speed, accuracy, sensitivity, selectivity, cost, portability, reliability, and user friendliness. Throughout the decades, tremendous progress has been made in point-of-care microdevices for viral infectious diseases. In this paper, we review fully integrated lab-on-chip systems for blood analysis of viral infectious disease.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7088150PMC
http://dx.doi.org/10.1007/s10439-014-1044-2DOI Listing

Publication Analysis

Top Keywords

point-of-care microdevices
12
blood plasma
12
viral infectious
12
analysis viral
8
infectious diseases
8
plasma biomarker
8
blood
5
plasma
5
viral
5
microdevices blood
4

Similar Publications

Smartphone-driven centrifugal microfluidics for diagnostics in resource limited settings.

Biomed Microdevices

October 2024

Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden.

The broad availability of smartphones has provided new opportunities to develop less expensive, portable, and integrated point-of-care (POC) platforms. Here, a platform that consists of three main components is introduced: a portable housing, a centrifugal microfluidic disc, and a mobile phone. The mobile phone supplies the electrical power and serves as an analysing system.

View Article and Find Full Text PDF

Background: India relies primarily on direct smear microscopy for tuberculosis (TB) diagnosis. However, the low sensitivity of smear microscopy emphasizes the need to improve its performance. We recently described the development of 'TB' kit which showed improved performance over direct smear microscopy at National Reference Laboratories (NRLs) in India.

View Article and Find Full Text PDF

Microfluidic-based point-of-care diagnostics offer several unique advantages over existing bioanalytical solutions, such as automation, miniaturisation, and integration of sensors to rapidly detect on-site specific biomarkers. It is important to highlight that a microfluidic POC system needs to perform a number of steps, including sample preparation, nucleic acid extraction, amplification, and detection. Each of these stages involves mixing and elution to go from sample to result.

View Article and Find Full Text PDF

Rapid ultrasensitive and specific BNP biosensor with LED readout.

Biomed Microdevices

May 2024

Department of Electrical and Computer Engineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, US.

Biosensing for diagnostics has risen rapidly in popularity over the past decades. With the discovery of new nanomaterials and morphologies, sensitivity is being constantly improved enough for reliable detection of trace biomarkers in human samples, like serum or sweat. This precision has enabled detailed research on the efficacy of biosensors.

View Article and Find Full Text PDF

Micropump integrated white blood cell separation platform for detection of chronic granulomatous disease.

Mikrochim Acta

May 2024

Department of Mechanical Engineering, BITS-Pilani, K K Birla Goa Campus, Sankval, Goa, 403726, India.

White blood cells (WBCs) are robust defenders during antigenic challenges and prime immune cell functioning indicators. High-purity WBC separation is vital for various clinical assays and disease diagnosis. Red blood cells (RBCs) are a major hindrance in WBC separation, constituting 1000 times the WBC population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!