Background: Operative hemorrhoidectomy can result in pain and altered continence from excessive excision of anoderm or surrounding tissue. We assessed a novel low-profile slotted anoscope to determine if the device would promote safe dissection, lessen trauma, and reduce operative times for hemorrhoidectomy.

Methods: Patients requiring hemorrhoidectomy (June 2008 - January 2010) underwent a prospective phase-2 trial evaluating a new operating anoscope (CAD, Ethicon Endosurgery, Cincinnati, OH). Demographics and perioperative end points including bleeding, pain, fecal incontinence, stenosis, and symptom recurrence were analyzed at 4 weeks, 3 months, 6 months, and 1 year postoperatively. We compared these to patients undergoing hemorrhoidectomy (February 2010 - November 2012) with a traditional Hill-Ferguson anoscope (THF).

Results: 40 patients (CAD, 20 vs THF, 20) were included. Presenting symptoms were similar, whereas mean duration of symptoms was longer for CAD (41.2 ± 8.4 vs 27 ± 9.5 months; P < .05). Estimated blood loss was lower for CAD [8.3 mL (range = 2-40 mL) vs 11.3 mL THF (range = 5-35 mL; P = .87)]. Mean operative times were lower for the CAD than the THF group (15.6 ± 3.4 vs 26.1 ± 4.1 minutes; P < .05). Visual analog pain scores were non-significantly increased in the THF group at 4 weeks (P = .23). At 3 months, 6 months, and 1 year, there was no difference in continence.

Conclusion: The CAD anoscope reduced operative times for modified Ferguson (closed) hemorrhoidectomy when compared with traditional retractors. There was no difference in incontinence or pain between groups.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1553350614535859DOI Listing

Publication Analysis

Top Keywords

operative times
12
weeks months
8
months months
8
months year
8
cad thf
8
lower cad
8
thf group
8
cad
6
anoscope
5
hemorrhoidectomy
5

Similar Publications

Background: The purpose of this study was to compare the outcomes of Trans-umbilical single-port laparoscopic complete extraperitoneal closure (LCEC) and laparoscopic intracorporeal closure (LIC) for inguinal hernia by analysis of follow-up data over 5 years.

Methods: In this prospective randomized controlled trial, 524 children with inguinal hernia were randomly assigned to undergo LCEC or LIC between August 2016 and December 2017. The primary outcome measures were the success and recurrence rates.

View Article and Find Full Text PDF

The rapid growth, invasiveness, and resistance to treatment of glioblastoma multiforme (GBM) underscore the urgent need for improved diagnostics and therapies. Current surgical practice is limited by challenges with intraoperative imaging, while recurrence monitoring requires expensive magnetic resonance or nuclear imaging scans. Here we introduce 'acoustic tumor paint', an approach to labeling brain tumors for ultrasound imaging, a widely accessible imaging modality.

View Article and Find Full Text PDF

Background: Over the last decade, numerous efforts have been made to combat the opioid crisis globally. The impact of these strategies has not been adequately measured and may differ across populations depending on baseline risk. We compared changes in long-term prescription opioid use following surgery within a national US cohort, between 2017 and 2022.

View Article and Find Full Text PDF

Objectives: Several devices have been developed to improve head and neck surgery. 3D exoscopes provide surgeons a viable alternative to microscopes. We propose our setting for transoral exoscopic oropharyngeal (TOEOS) and transoral exoscopic laryngeal surgery (TOELS).

View Article and Find Full Text PDF

Fracture Resistance of Chairside CAD/CAM Lithium Disilicate Partial and Full Coverage Crowns and Veneers for Maxillary Canines.

Oper Dent

January 2025

Nathaniel C Lawson, DDS, PhD, director of Master of Science in Dental Biomaterials program and associate professor, Department of Clinical and Community Sciences, University of Alabama at Birmingham School of Dentistry, Birmingham, AL, USA.

Objective: This study aimed to assess the fracture resistance of chairside computer assisted design and computer assisted manufacturing (CAD-CAM) lithium disilicate partial and full-coverage crowns and veneers for maxillary canines.

Methods And Materials: Forty-eight restorations for maxillary right canines (12 per group) were designed as follows: (1) partial crown with finish line in the upper middle third; (2) partial crown with finish line in the lower middle third; (3) traditional labial veneer; and (4) traditional full-coverage crown. Restorations were fabricated out of lithium disilicate (Amber Mill, Hassbio) using a chairside CAD-CAM system (Cerec Dentsply Sirona).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!