Introduction: Heubner's recurrent artery (RAH) in brain selective catheter angiograms (digital subtraction angiography, DSA) was evaluated.
Methods: Bilateral cerebral angiograms with antero-posterior, lateral and oblique frontal views were obtained in 100 neurological patients aged from 5 to 90 years. Site of origin, type of course and branching of the RAH were studied. Three groups were obtained: arteries with solely the horizontal segment visible, horizontal and vertical segments visible and horizontal and vertical with intraparenchymal branches visible.
Results: A total of 24 RAHs were recognised in 20 patients: 7 arose from the A1, 5 from the anterior cerebral artery (ACA)-anterior communicating artery (Acom), 11 from the A2, whereas in 1 case, the segment of origin from the ACA could not be identified. Seventeen arteries arose from the lateral wall of the ACA and seven from the superior wall of the A1 segment of the ACA. The RAH was bilaterally seen in 3 patients and unilaterally in 17 with one double RAH. Five RAHs were visible only after contrast injection in the contralateral internal carotid artery. A horizontal segment was visible in 7 arteries, a horizontal followed by a vertical segment without visible intraparenchymal branching pattern was seen in 6 and a horizontal and vertical segment with visible intraparenchymal branching pattern was seen in 11. In five, the artery made a half loop with an inferior-convex curve just before the vertical segment, and in two cases, a full loop was observed.
Conclusion: The RAH was recognised in 12% of the hemispheres of the present series of neurological patients studied with DSA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00234-014-1387-2 | DOI Listing |
Insights Imaging
January 2025
Diagnostic and Interventional Radiology, University Hospital of Zurich, University Zurich, Zurich, Switzerland.
Objectives: To compare and correlate bone edema volume detected by 3D-short-tau-inversion-recovery (STIR) sequence to osseous decay detected by a T1-based sequence and conventional panoramic radiography (OPT).
Materials And Methods: Patients with clinical evidence of apical periodontitis were included retrospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR and a 3D-T1 gradient echo sequence. Bone edema was visualized using the 3D-STIR sequence and periapical hard tissue changes were evaluated using the 3D-T1 sequence.
Radiother Oncol
January 2025
Department of Radiation Oncology Olivia Newton-John Cancer Wellness & Research Centre Austin Health Victoria Australia; Department of Medical Imaging and Radiation Sciences, Monash University Clayton Victoria Australia; Genesis Care, Ringwood Private Hospital Victoria Australia.
Background And Purpose: Compare breast cancer tumour bed (TB) delineation using stabilised hyaluronic acid (sHA) gel and MRI-simulation versus surgical clips and CT-simulation within same patient cohort.
Materials And Methods: Prospective single arm study of patients undergoing breast conserving surgery. Patients had both clips (≥5) and sHA gel markers inserted to define the TB and underwent MRI and CT simulation scans.
NMR Biomed
March 2025
Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
Gliomas are highly heterogeneous and often include a nonenhancing component that is hyperintense on T weighted MRI. This can often not be distinguished from secondary gliosis and surrounding edema. We hypothesized that the extent of these T hyperintense areas can more accurately be determined on high-quality 7 T MRI scans.
View Article and Find Full Text PDFIEEE Trans Instrum Meas
May 2024
School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China.
Automatic retinal layer segmentation with medical images, such as optical coherence tomography (OCT) images, serves as an important tool for diagnosing ophthalmic diseases. However, it is challenging to achieve accurate segmentation due to low contrast and blood flow noises presented in the images. In addition, the algorithm should be light-weight to be deployed for practical clinical applications.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2025
Changchun Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Changchun 130122 China. Electronic address:
Human serum albumin (HSA) is a key protein implicates in various physiological and pathological conditions such as renal injury, diabetes mellitus. Herein, we report an AIE-active fluorescent probe (DNI-4) for detection of HSA with a "turn on" response covering visible and near-infrared region (500 - 800 nm). Combining with a triphenylamine and two 1,8-naphthalimide moieties, the chromophore segment of DNI-4 forms a "A-D-A" type molecular architecture with the twisted intramolecular charge transfer property.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!