Biomechanical analysis is a powerful tool in the evaluation of movement dysfunction in orthopaedic and neurologic populations. Three-dimensional (3D) motion capture systems are widely used, accurate systems, but are costly and not available in many clinical settings. The Microsoft Kinect™ has the potential to be used as an alternative low-cost motion analysis tool. The purpose of this study was to assess concurrent validity of the Kinect™ with Brekel Kinect software in comparison to Vicon Nexus during sagittal plane gait kinematics. Twenty healthy adults (nine male, 11 female) were tracked while walking and jogging at three velocities on a treadmill. Concurrent hip and knee peak flexion and extension and stride timing measurements were compared between Vicon and Kinect™. Although Kinect measurements were representative of normal gait, the Kinect™ generally under-estimated joint flexion and over-estimated extension. Kinect™ and Vicon hip angular displacement correlation was very low and error was large. Kinect™ knee measurements were somewhat better than hip, but were not consistent enough for clinical assessment. Correlation between Kinect™ and Vicon stride timing was high and error was fairly small. Variability in Kinect™ measurements was smallest at the slowest velocity. The Kinect™ has basic motion capture capabilities and with some minor adjustments will be an acceptable tool to measure stride timing, but sophisticated advances in software and hardware are necessary to improve Kinect™ sensitivity before it can be implemented for clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.3109/03091902.2014.909540DOI Listing

Publication Analysis

Top Keywords

motion capture
12
stride timing
12
kinect™
10
kinect™ vicon
8
vicon
5
comparative abilities
4
abilities microsoft
4
microsoft kinect
4
kinect vicon
4
motion
4

Similar Publications

Anticipatory postural adjustments (APAs) are responsible for a successful first step execution in handstand walking. This study evaluates gymnasts' ability to adapt their APAs and stepping parameters in response to adding/removing an external load over repeated handstand walking initiation trials. Eighteen gymnasts performed five handstand walking initiation trials without load (PRE), eight trials with an external load (LOAD) and five trials with removed load (POST).

View Article and Find Full Text PDF

Photoacoustic microscopy has demonstrated outstanding performance in high-resolution functional imaging. However, in the process of photoacoustic imaging, the photoacoustic signals will be polluted by inevitable background noise. Besides, the image quality is compromised due to the biosafety limitation of the laser.

View Article and Find Full Text PDF

Expansion of perceived passable width in older adults.

Hum Mov Sci

January 2025

Faculty of Humanities and Social Sciences (Psychology), Kumamoto University, 2-40-1 Kurokami, Kumamoto 860-8555, Japan.

Humans can perceive whether an aperture is passable; this ability is known as passable width perception. Previous studies have shown that passable width in older adults is larger when walking and suggested the effect of larger body sway in older adults while walking on passable width expansion. However, no studies have directly investigated this.

View Article and Find Full Text PDF

Core-Excited States for Open-Shell Systems in Similarity-Transformed Equation-of-Motion Theory.

J Chem Theory Comput

January 2025

Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, 45470 Mülheim an der Ruhr, Germany.

X-ray absorption spectroscopy (XAS) is a powerful method for exploring molecular electronic structure by exciting core electrons into higher unoccupied molecular orbitals. In this study, we present the first integration of the spin-unrestricted similarity-transformed equation-of-motion coupled cluster method (CVS-USTEOM-CCSD) for core-excited and core-ionized states into the ORCA quantum chemistry package. Using the core-valence separation (CVS) approach, we evaluate the accuracy of CVS-USTEOM-CCSD across 13 open-shell organic systems, covering over 20 core excitations with diverse spin multiplicities (doublet, triplet, and quartet).

View Article and Find Full Text PDF

Introduction: Wrist-worn accelerometers can capture stepping behavior passively, continuously, and remotely. Methods utilizing peak detection, threshold crossing, and frequency analysis have been used to detect steps from wrist-worn accelerometer data, but it remains unclear how different approaches perform across a range of walking speeds and free-living activities. In this study, we evaluated the performance of four open-source methods for deriving step counts from wrist-worn accelerometry data, when applied to data from a range of structured locomotion and free-living activities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!