The rigidity of framework materials and overload of the implant system directly affect the final transferred load of the bone around implants. The aim of the present study has been to analyse the influence of framework materials on the transferred load to the implant system and the surrounding bone. A finite element model of a long-span cementable implant-supported fixed prosthesis was created with two coping layers (gold and hybrid composite) to optimise the fitting of the prosthesis to the abutments. Three framework materials were analysed: titanium, gold alloy, and zirconia. The connection screws were first preloaded with 200 N. The framework was then loaded with 500 N vertically and at 30° to the framework long axis. Two loading conditions were considered: at the mesial and distal boundaries of the framework and at the centre of the framework. The stresses and strains within the framework materials and bone bed around the supporting implants were analysed. The region and angle of load applications showed an obvious effect on the values of the stresses and strains within the framework itself and, consequently, their distribution in the implant system and surrounding bone. A correlation of the framework material and stresses of the coping materials was observed as well. The gold framework showed acceptable values of stress within the cortical bone (92 MPa and 89 MPa with 30° loading at two points and at the centre, respectively) in comparison to titanium (92 MPa and 113 MPa) and zirconia (88 MPa and 115 MPa).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aanat.2014.03.005 | DOI Listing |