A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Development and analytical validation according COFRAC recommendations of pyruvate and ketone body assay on open automated analyser]. | LitMetric

[Development and analytical validation according COFRAC recommendations of pyruvate and ketone body assay on open automated analyser].

Ann Biol Clin (Paris)

Laboratoire des maladies héréditaires du métabolisme, biochimie génétique et moléculaire, Département de biochimie, toxicologie et pharmacologie, CHU de Grenoble site Nord - Institut de biologie et de pathologie, Grenoble, France.

Published: May 2016

Measurements of pyruvate and ketones bodies (acetoacetate and 3-hydroxybutyrate) are essential to the investigation of intermediary metabolism. Indeed, their blood levels reflect energy balance influenced by nutritional status. This balance can be disturbed in certain diseases such as diabetes and some inherited metabolic disorders. We have developed methods for assays on open automated biochemistry analyser, Konelab 20 XT (ThermoFischer, Whaltham USA), using kits marketed by Sobioda (Montbonnot, France) for pyruvate and Wako Chemicals GmbH (Neuss, Germany) for ketones, on deproteinised blood sample. We have validated the performance of these three quantitative methods using NF EN ISO 15189 (range B) standard criteria. We obtain satisfactory results concerning fidelity (precision measured as within and between batch CVs are respectively less than 7% and less than 6%), measuring ranges (from 7.7 to 228 μmol/L for pyruvate and from 22.6 to 650 μM for total ketone bodies), accuracy (10.4 μmol/L in physiological range for pyruvate and 7.1 μmol/L for 3-hydroxybutyrate) and comparing methods (versus manual assay with spectrophotometry on Uvikon XL). Establishment of reference ranges (35 to 74 μmol/L for pyruvate, less than 100 μM for 3-hydroxybutyrate and less than 44 μmol/L for acetoacetate) and reagents stability study (up to 12 weeks if frozen) have enabled us to finalize method validation and to add these assays to our routine laboratory repertoire.

Download full-text PDF

Source
http://dx.doi.org/10.1684/abc.2014.0950DOI Listing

Publication Analysis

Top Keywords

open automated
8
μmol/l pyruvate
8
pyruvate
6
μmol/l
5
[development analytical
4
analytical validation
4
validation cofrac
4
cofrac recommendations
4
recommendations pyruvate
4
pyruvate ketone
4