This paper describes a mixed-signal ECG System-on-Chip (SoC) that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channel electrode-tissue-impedance (ETI) measurement with high signal quality. This can be used to evaluate the quality of the ECG measurement and to filter motion artifacts. A custom digital signal processor consisting of 4-way SIMD processor provides the configurability and advanced functionality like motion artifact removal and R peak detection. A built-in 12-bit analog-to-digital converter (ADC) is capable of adaptive sampling achieving a compression ratio of up to 7, and loop buffer integration reduces the power consumption for on-chip memory access. The SoC is implemented in 0.18 μm CMOS process and consumes 32 μ W from a 1.2 V while heart beat detection application is running, and integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the ECG SoC, the overall system power consumption can be reduced significantly.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBCAS.2013.2260159DOI Listing

Publication Analysis

Top Keywords

ecg monitoring
12
portable ecg
8
monitoring applications
8
power consumption
8
ecg
7
configurable low-power
4
low-power mixed
4
mixed signal
4
soc
4
signal soc
4

Similar Publications

Exercise has a significant impact on the cardiovascular (CV) health of children and adolescents, with resultant alterations in CV structure and function being evident, even at an early age. Engagement in regular, moderate physical activity (PA) is associated with long-term CV health benefits and a reduced risk of CV disease and mortality later in life. However, competitive sports often involve PA training intensities that are beyond recommended levels for young athletes, potentially leading to adverse CV outcomes.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia. Given its often-paroxysmal nature, screening at a single time point, using a 12-lead electrocardiogram (ECG) or a Holter monitor, has limited benefit. The AliveCor KardiaMobile device is a validated ECG recorder that can be used for patient-directed arrhythmia diagnosis and symptom-rhythm correlation.

View Article and Find Full Text PDF

High altitude pulmonary oedema: Mimicker of acute coronary syndrome.

Med J Armed Forces India

December 2024

Clinical Tutor, Department of Internal Medicine, Armed Forces Medical College, C/o 56 APO, India.

High altitude pulmonary oedema (HAPO) is a common emergency seen at high altitude. It can be associated with electrocardiogram (ECG) changes due to pulmonary arterial hypertension in the form of ST elevation and T wave inversion in the right precordial leads, which mimic acute coronary syndrome. These changes can lead to confusion in diagnosis and management.

View Article and Find Full Text PDF

Background: Numerous studies have demonstrated the significance of trimethylamine-N-oxide (TMAO) in the progression of atrial fibrillation (AF). However, the association between TMAO and AF recurrence (RAF) post-catheter ablation is not yet fully understood. This study aims to elucidate the predictive capability of pre-procedural TMAO levels in determining RAF following catheter ablation (CA).

View Article and Find Full Text PDF

Monitoring respiration rate (RR) is crucial in various healthcare settings, particularly during demanding (physical) activities where respiratory dynamics are critical indicators of health status. This study aimed to evaluate the accuracy of photoplethysmography (PPG)-based monitoring of RR during high-intensity interval training (HIIT) and its potential applications in healthcare. Between January and March 2024, healthy volunteers participated in a cycling HIIT session with increasing resistance levels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!