The aim of this study was to compare the various dosimetric parameters of dynamic multileaf collimator (MLC) intensity modulated radiation therapy (IMRT) plans with volumetric modulated arc therapy (VMAT) plans for base of tongue cases. All plans were done in Monaco planning system for Elekta synergy linear accelerator with 80 MLC. IMRT plans were planned with nine stationary beams, and VMAT plans were done for 360° arc with single arc or dual arc. The dose to the planning target volumes (PTV) for 70, 63, and 56 Gy was compared. The dose to 95, 98, and 50% volume of PTV were analyzed. The homogeneity index (HI) and the conformity index (CI) of the PTV70 were also analyzed. IMRT and VMAT plan showed similar dose coverage, HI, and CI. Maximum dose and dose to 1-cc volume of spinal cord, planning risk volume (PRV) cord, and brain stem were compared. IMRT plan and VMAT plan showed similar results except for the 1 cc of PRV cord that received slightly higher dose in VMAT plan. Mean dose and dose to 50% volume of right and left parotid glands were analyzed. VMAT plan gave better sparing of parotid glands than IMRT. In normal tissue dose analyses VMAT was better than IMRT. The number of monitor units (MU) required for delivering the good quality of the plan and the time required to deliver the plan for IMRT and VMAT were compared. The number of MUs for VMAT was higher than that of IMRT plans. However, the delivery time was reduced by a factor of two for VMAT compared with IMRT. VMAT plans yielded good quality of the plan compared with IMRT, resulting in reduced treatment time and improved efficiency for base of tongue cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4035616PMC
http://dx.doi.org/10.4103/0971-6203.131288DOI Listing

Publication Analysis

Top Keywords

vmat plan
16
base tongue
12
imrt plans
12
vmat plans
12
imrt vmat
12
compared imrt
12
vmat
11
imrt
10
dose
9
arc therapy
8

Similar Publications

Background And Purpose: In lung stereotactic body radiation therapy (SBRT) using a breath-holding technique, displacement of tumor during breath-holding is rarely considered. This study used four-dimensional (4D) dose calculation with cine computed tomography (CT) to evaluate the impact of unexpected tumor position displacement during breath-holding on the target dose of lung volumetric modulated arc therapy (VMAT)-SBRT.

Materials And Methods: This study included 20 cases for which tumor position displacement during end-exhalation breath-holding (range: 0.

View Article and Find Full Text PDF

Photon mini-GRID therapy for preoperative breast cancer tumor treatment: A treatment plan study.

Med Phys

January 2025

Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, Orsay, France.

Background: Breast cancer is the leading cause of female cancer mortality worldwide, accounting for 1 in 6 cancer deaths. Surgery, radiation, and systemic therapy are the three pillars of breast cancer treatment, with several strategies developed to combine them. The association of preoperative radiotherapy with immunotherapy may improve breast cancer tumor control by exploiting the tumor radio-induced immune priming.

View Article and Find Full Text PDF

Background: The treatment of glioblastomas (GBM) with radiation therapy is extremely challenging due to their invasive nature and high recurrence rate within normal brain tissue.

Purpose: In this work, we present a new metric called the tumour spread (TS) map, which utilizes diffusion tensor imaging (DTI) to predict the probable direction of tumour cells spread along fiber tracts. We hypothesized that the TS map could serve as a predictive tool for identifying patterns of likely recurrence in patients with GBM and, therefore, be used to modify the delivery of radiation treatment to pre-emptively target regions at high risk of tumour spread.

View Article and Find Full Text PDF

Comparing the Robustness of Intensity-modulated Proton Therapy and Proton-arc Therapy Against Interplay Effects of 4D Robust-optimised Plans for Lung Stereotactic Body Radiotherapy.

Clin Oncol (R Coll Radiol)

January 2025

Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China; Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China.

Aims: To assess the robustness of 4D-optimised IMPT and PAT plans against interplay effects in non-small cell lung cancer (NSCLC) patients with respiratory motion over 10 mm, and to provide insights into the use of proton-based stereotactic body radiotherapy (SBRT) for lung cancer with significant tumour movement.

Materials And Methods: Fourteen patients with early-stage NSCLC and tumour motion >10 mm were selected. Three hypofraction regimens were generated using 4D robust optimisation with the IMPT and PAT techniques.

View Article and Find Full Text PDF

Purpose: Conventional radiotherapy (CRT) has limited local control and poses a high risk of severe toxicity in large lung tumors. This study aimed to develop an integrated treatment plan that combines CRT with lattice boost radiotherapy (LRT) and monitors its dosimetric characteristics.

Methods: This study employed cone-beam computed tomography from 115 lung cancer patients to develop a U-Net +  + deep learning model for generating synthetic CT (sCT).

View Article and Find Full Text PDF