Chronopotentiometric carbonate detection with all-solid-state ionophore-based electrodes.

Anal Chem

Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland.

Published: July 2014

We present here for the first time an all-solid-state chronopotentiometric ion sensing system based on selective ionophores, specifically for the carbonate anion. A chronopotentiometric readout is attractive because it may allow one to obtain complementary information on the sample speciation compared to zero-current potentiometry and detect the sum of labile carbonate species instead of only ion activity. Ferrocene covalently attached to the PVC polymeric chain acts as an ion-to-electron transducer and provides the driving force to initiate the sensing process at the membrane-sample interface. The incorporation of a selective ionophore for carbonate allows one to determine this anion in a background electrolyte. Various inner electrolyte and all-solid-state-membrane configurations are explored, and localized carbonate depletion is only observed for systems that do not contain ion-exchanger additives. The square root of the transition times extracted from the inflection point of the chronopotentiograms as a function of carbonate specie concentration follows a linear relationship. The observed linear range is 0.03-0.35 mM in a pH range of 9.50-10.05. By applying the Sand equation, the diffusion coefficient of carbonate is calculated as (9.03 ± 0.91) 10(-6) cm(2) s(-1), which corresponds to the established value. The reproducibility of assessed carbonate is better than 1%. Additionally, carbonate is monitored during titrimetric analysis as a precursor to an in situ environmental determination. Based on these results, Fc-PVC membranes doped with ionophores may form the basis of a new family of passive/active all-solid-state ion selective electrodes interrogated by a current pulse.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac5004163DOI Listing

Publication Analysis

Top Keywords

carbonate
8
chronopotentiometric carbonate
4
carbonate detection
4
detection all-solid-state
4
all-solid-state ionophore-based
4
ionophore-based electrodes
4
electrodes time
4
time all-solid-state
4
all-solid-state chronopotentiometric
4
chronopotentiometric ion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!