Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Open digestate storage tanks were identified as one of the main methane (CH4) emitters of a biogas plant. The main purpose of this paper is to determine these emission rates using an inverse dispersion technique in conjunction with open-path tunable diode laser spectroscopy (OP-TDLS) concentration measurements for multisource reconstruction. Since the condition number, a measure of "ill-conditioned" matrices, strongly influences the accuracy of source reconstruction, it is used as a diagnostic of error sensitivity. The investigations demonstrate that the condition number for a given source-sensor configuration in the highly disturbed flow field within the plant significantly depends on the meteorological conditions (e.g., wind speed, stratification, wind direction, etc.). The CH₄ emissions are retrieved by removing unrepresentative periods with high condition numbers, which indicate uncertainty in recovering the individual sources. In a final step, the CH₄ emissions are compared with the maximum biological methane potential (BMP) in the digestate analyzed under laboratory conditions. The retrieved methane emission rates represent an average of 50% of the maximum BMP of the stored digestate in the winter months, while they comprised an average of 85% during the measurement campaigns in the summer months. The results indicate that the open tanks have the potential to represent a substantial emission source even during colder periods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10661-014-3852-0 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!