A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multisource emission retrieval within a biogas plant based on inverse dispersion calculations--a real-life example. | LitMetric

Multisource emission retrieval within a biogas plant based on inverse dispersion calculations--a real-life example.

Environ Monit Assess

Department of Water-Atmosphere-Environment, Institute of Waste Management, University of Natural Resources and Life Sciences, Muthgasse 107, 1190, Vienna, Austria,

Published: October 2014

Open digestate storage tanks were identified as one of the main methane (CH4) emitters of a biogas plant. The main purpose of this paper is to determine these emission rates using an inverse dispersion technique in conjunction with open-path tunable diode laser spectroscopy (OP-TDLS) concentration measurements for multisource reconstruction. Since the condition number, a measure of "ill-conditioned" matrices, strongly influences the accuracy of source reconstruction, it is used as a diagnostic of error sensitivity. The investigations demonstrate that the condition number for a given source-sensor configuration in the highly disturbed flow field within the plant significantly depends on the meteorological conditions (e.g., wind speed, stratification, wind direction, etc.). The CH₄ emissions are retrieved by removing unrepresentative periods with high condition numbers, which indicate uncertainty in recovering the individual sources. In a final step, the CH₄ emissions are compared with the maximum biological methane potential (BMP) in the digestate analyzed under laboratory conditions. The retrieved methane emission rates represent an average of 50% of the maximum BMP of the stored digestate in the winter months, while they comprised an average of 85% during the measurement campaigns in the summer months. The results indicate that the open tanks have the potential to represent a substantial emission source even during colder periods.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10661-014-3852-0DOI Listing

Publication Analysis

Top Keywords

biogas plant
8
inverse dispersion
8
emission rates
8
condition number
8
ch₄ emissions
8
multisource emission
4
emission retrieval
4
retrieval biogas
4
plant based
4
based inverse
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!