Aim: To test the null hypothesis was that there is no difference in the shear strength of indirectly bonded lingual brackets with or without prior application of metal primer on their bases.

Materials And Methods: Forty recently extracted human premolars were obtained and randomly divided into two groups of 20 each: group I (control), phosphoric acid and indirect bonding with Maximum Cure (Reliance Orthodontic Products, Itasca, IL, USA); and group II, application of metal primer (Metal Primer, Reliance Orthodontic Products) on bracket base prior to conditioning and indirect bonding. All products were used according to the manufacturer's instructions. A universal testing machine was used to apply a shear force directly onto the enamel- bracket interface at a speed of 1.0 mm/min.

Results: Mean (SD) shear bond strength for group I was 12.87 (5.75) MPa and for the group II was 18.47 (8.48) MPa. The Student's t-test showed a significant difference (p = 0.0311) between the groups. The chi-square test for the adhesive remnant index (ARI) indicated that there was a significant difference (p = 0.2750).

Conclusion: The application of metal primer increased the adhesion of lingual brackets, and may be a promising procedure for clinical orthodontics.

Download full-text PDF

Source
http://dx.doi.org/10.5005/jp-journals-10024-1459DOI Listing

Publication Analysis

Top Keywords

metal primer
20
lingual brackets
12
application metal
12
indirect bonding
8
reliance orthodontic
8
orthodontic products
8
metal
5
primer adhesive
4
adhesive interface
4
interface composite
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!