Ventilation-perfusion (VQ) single-photon emission computed tomography (SPECT) comprised the administration of SmartVent (n=386) or Technegas (n=1564) and 200 MBq (99m)Tc-MAA. 1406 scans were normal, 462 showed PE, 61 showed a singular subsegmental mismatched defect, 21 scans were non-diagnostic. 26% of scans performed with Technegas showed PE, compared to 15% with SmartVent. VQ SPECT had a sensitivity of 95.7%, specificity 98.6%, positive predictive value 95.7%, negative predictive value 98.6%. A normal VQ SPECT scan implied a more than ten-fold lower cause-specific mortality (1 in 1406) than a scan showing PE (1 in 116). NPV of a negative D-dimer was 94.3%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clinimag.2014.04.003 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!