Calcium hydroxide [Ca(OH)2 ] residues in root canals may compromise sealing of filling and endodontic treatment success. The aim of this study was to compare the efficacy of using rotary instrument associated with EndoActivator, EndoVac, passive ultrasonic irrigation (PUI), and conventional needle irrigation (CNI), in Ca(OH)2 removal from root canal, by means of scanning electron microscopy (SEM) images. Sixty-six human canines were prepared with the Protaper system up to F5 and filled with Ca(OH)2 . After 7 days, Ca(OH)2 was removed with rotary instrument F5 associated with the irrigation techniques used in each group (n = 15): GI (CNI), GII (EndoVac), GIII (EndoActivator) and GIV (PUI). In all groups 15 mL of 2.5% NaOCl and 3 mL of 17% EDTA were used for Ca(OH)2 removal. The Ca(OH)2 residues was evaluated by SEM in the middle and apical third using a system of scores. The results were analyzed by the Kruskal-Wallis and Dunn tests (α = 0.05). None of the techniques completely removed the Ca(OH)2 from root canals. There was no difference between EndoActivator, EndoVac and PUI (P > 0.05), but the three techniques removed more Ca(OH)2 than the CNI (P < 0,05), in the middle and apical thirds of the root canal. It was concluded that the rotary instrument combined with EndoActivator, EndoVac, and PUI was shown to be more efficient than the rotary instrument combined with the CNI in removing Ca(OH)2 from the root canal.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jemt.22382DOI Listing

Publication Analysis

Top Keywords

rotary instrument
20
instrument associated
12
endoactivator endovac
12
root canal
12
associated irrigation
8
irrigation techniques
8
calcium hydroxide
8
root canals
8
caoh2
8
caoh2 removal
8

Similar Publications

A polarimeter is a common but critical instrument for measuring the optical rotation of chiral compounds, ranging from the pharmaceutical to chemical industry, or even employed in monitoring chemical reactions for research purposes. Developing a portable polarimeter helps to transfer the measurements from the laboratory to on-site detection. Herein, we design a new portable polarimeter with a "hand-held" scale.

View Article and Find Full Text PDF

Introduction: This is a double clinical trial conducted to study the patient satisfaction and comfort during and after surgical removal of impacted mandibular 3rd molar using Piezo electric tips.

Material And Methods: Two groups of 25 each [14 (56 %) males and 11 (44 %) females] and [18 (72 % males and 07 (28 %) females] represented the Rotary and Piezo groups respectively with bilateral impactions. one side of the patient is operated by piezo and the other side by rotary instrument after a gap of 2-3 week between the procedures.

View Article and Find Full Text PDF

This study compared the apical transportation and centering ratio of ProTaper Next (PTN) and XP-endo Shaper (XPS) nickel titanium (NiTi) rotary files in curved root canals using cone beam computed tomography (CBCT). The current in vitro study involved the mesiobuccal canals of mesial roots in 44 extracted mandibular first molars that exhibited apical curvature ranging from 10° to 30°. Two experimental groups were randomly formed from the teeth ( = 22) and subjected to instrumentation with PTN and XPS.

View Article and Find Full Text PDF

Sensitive, rapid and label-free biochemical sensors are needed for many applications. In this protocol, we describe biochemical detection using FLOWER (frequency locked optical whispering evanescent resonator)-a technique that we have used to detect single protein molecules in aqueous solution as well as exosomes, ribosomes and low part-per-trillion concentrations of volatile organic compounds. Whispering gallery mode microtoroid resonators confine light for extended time periods (hundreds of nanoseconds).

View Article and Find Full Text PDF

Effect of mechanical instrumentation on titanium implant surface properties.

Dent Mater

January 2025

Department of Materials, School of Natural Sciences, University of Manchester, Manchester M13 9PL, UK; Photon Science Institute, University of Manchester, Manchester M13 9PL, UK. Electronic address:

Objective: To assess the impact of mechanical decontamination using rotary brushes on the surface topography, elemental composition, roughness, and wettability of titanium implant surfaces.

Methods: Four commercially available rotary brushes were used: Labrida BioClean Brush® (LB), i-Brush1 (IB), NiTiBrush Nano (NiTiB), and Peri-implantitis Brush (PIB). Seventy-five titanium discs with sandblasted, large-grit, acid-etched (SLA) surfaces were randomly assigned to five groups (n = 15): LB, IB, NiTiB, PIB, and a control group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!