A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The flaws of laser Doppler in negative-pressure wound therapy research. | LitMetric

The flaws of laser Doppler in negative-pressure wound therapy research.

Wound Repair Regen

Department of Plastic, Reconstructive and Maxillo-Facial Surgery, University of Cape Town and Groote Schuur Hospital, Cape Town, South Africa.

Published: February 2015

Recent studies, using modalities other than laser Doppler, have indicated that perfusion during negative-pressure wound therapy (NPWT) is reduced, contrary to world literature. The aim of the present study was to evaluate whether the measuring technique of the laser Doppler could be influenced by the compressive nature of NPWT dressings and whether this could explain the conflicting findings. A hypothesis that it may be possible for laser Doppler to record similar readings to those obtained during NPWT by merely compressing tissues manually was tested on 12 NPWT dressings, with each undergoing an alternating series of manual compressive forces and NPWT (-125 mmHg). During the periods of NPWT (n = 12), the mean perfusion recording increased in five experiments, reduced in six, and remained unchanged in one. During the period when manual pressure was applied (n = 12), there was a mean increase in perfusion in six experiments and a reduction in six. The type of change in perfusion (increase or decrease) was the same for both NPWT and manual pressure in 10 of the 12 experiments. In conclusion, laser Doppler can incorrectly record increased perfusion when tissues are compressed, implying that it is flawed in the field of NPWT research as tissues are always compressed to some degree by the NPWT dressing.

Download full-text PDF

Source
http://dx.doi.org/10.1111/wrr.12168DOI Listing

Publication Analysis

Top Keywords

laser doppler
20
npwt
9
negative-pressure wound
8
wound therapy
8
npwt dressings
8
manual pressure
8
tissues compressed
8
doppler
5
perfusion
5
flaws laser
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!