Effect of dietary selenium and tumor status on the retention of 75Se by tissues and mammary tumors of DMBA-treated rats.

Biol Trace Elem Res

Nutrition Research Division, Health and Welfare Canada, Ottawa, Ontario.

Published: October 1990

The effects of the presence of mammary tumors on 75Se retention was examined in DMBA-treated rats. Tumor bearing rats fed varying amounts of Se exhibited an inverse linear dose response between dietary Se intake and tissue retention of 75Se in whole body, heart, lungs, ovaries, adrenals, spleen, and muscle. Tumor 75Se retention, however, was independent of the dietary intake of Se. Tumor bearing rats excreted more 75 Se label in the urine compared to both control rats fed the same amount of Se and DMBA-treated animals that remained tumor free. In the short term, no significant differences were seen in tissue retention of 75Se. By 7 d, the increased urinary excretion of the label resulted in significantly decreased retention of 75Se in blood, spleen, liver, lungs, and kidneys of tumor-bearing rats compared to tumor-free animals. The presence of tumors, however, did not affect the liver distribution of the label among cytosolic proteins. These results suggest that tumor bearing animals have an accelerated urinary excretion of Se compared to animals without tumors and that tumors either have a very slow turnover of Se or a low priority for the element.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02919110DOI Listing

Publication Analysis

Top Keywords

retention 75se
16
tumor bearing
12
mammary tumors
8
dmba-treated rats
8
75se retention
8
bearing rats
8
rats fed
8
dietary intake
8
tissue retention
8
urinary excretion
8

Similar Publications

Article Synopsis
  • Bile acid diarrhoea is often overlooked due to the limited availability of the SeHCAT test, which is considered the gold standard for diagnosis, and there are concerns regarding the diagnostic performance of empirical treatments and the less sensitive C4 blood tests.* -
  • A study involving 251 patients assessed the effectiveness of both the SeHCAT test and various methods including empirical treatment and C4 levels, finding that while empirical treatment showed moderate sensitivity and specificity, a decision tree model combining C4 and stool patterns provided better results.* -
  • The research concluded that the existing methods for diagnosing bile acid diarrhoea are insufficient, but improvements in C4 testing and alternative diagnostic models could enhance sensitivity and accessibility, warranting further validation
View Article and Find Full Text PDF

Efficacy and safety of colesevelam for the treatment of bile acid diarrhoea: a double-blind, randomised, placebo-controlled, phase 4 clinical trial.

Lancet Gastroenterol Hepatol

April 2023

Zealand University Hospital, Department of Internal Medicine, Køge, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.

Background: Bile acid diarrhoea is a common but overlooked cause of chronic watery diarrhoea. Plasma 7α-hydroxy-4-cholesten-3-one (C4) is an alternative to the gold standard tauroselcholic [Se] acid (SeHCAT) test. Low-certainty evidence supports sequestrant treatment, including colesevelam.

View Article and Find Full Text PDF

[75Se]tauroselcholic acid (SeHCAT) retention studies may be performed using a collimated or uncollimated (intrinsic) gamma camera, with trade-offs between counting sensitivity, collision risk, and stray source influence. In this work, we evaluate the uncertainty in SeHCAT studies performed in 'outer room' mode, where the patient sits or stands two metres away from the uncollimated camera face. 768 SeHCAT studies performed at the Royal Free Hospital were analysed retrospectively, and in all cases, the absolute uncertainty was found to be well within the clinically acceptable limit of ±1 percentage point at 15% retention.

View Article and Find Full Text PDF

Aim: There is increasing interest in using collimated gamma cameras for [75Se]tauroselcholic acid (SeHCAT) studies to image the distribution and to make use of the collimator pressure sensitive devices (PSD) for patient safety. However, the use of a collimator will substantially decrease the sensitivity of the gamma camera. The aim of this article is to enable departments to calculate the uncertainty of SeHCAT retention measurements so that the acquisition time can be optimised to perform a reliable SeHCAT study.

View Article and Find Full Text PDF

Metals and metalloids released through anthropogenic activities can accumulate in aquatic organisms, resulting in adverse effects in sensitive species. We investigated the influence of feeding regime and exposure complexity (i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!