X-ray image calibration and its application to clinical orthopedics.

Med Eng Phys

Institute for Surgical Technology and Biomechanics (ISTB), University of Bern, Switzerland. Electronic address:

Published: July 2014

X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1° for both anteversion and inclination angles, where in the second application an average displacement of 8.06±3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2014.04.001DOI Listing

Publication Analysis

Top Keywords

x-ray imaging
8
x-ray radiographs
8
x-ray calibration
8
calibration object
8
x-ray
7
x-ray image
4
calibration
4
image calibration
4
calibration application
4
application clinical
4

Similar Publications

Background And Objectives: Accurate intraoperative assessment of coronal alignment is critical to achieving favorable clinical outcomes in adult spinal deformity surgery. However, surgical positioning creates challenges in predicting standing coronal alignment. Gravity-based plumblines require an upright posture and are not possible intraoperatively.

View Article and Find Full Text PDF

Case: A 14-year-old male athlete presented with a 9-month history of low back pain, worse with hyperextension. Nonoperative management for bilateral L4 spondylolysis had been unsuccessful. The patient underwent a novel magnetic resonance imaging (MRI) that generated a synthetic computed tomography (sCT).

View Article and Find Full Text PDF

Case: A 30-year-old man presented with left proximal tibia fracture (open Grade 3A) and a transverse lateral malleolus fracture (Weber B) following direct impact injury. Computed tomography revealed a rare posteromedial tubercle fibula fracture at the posterior inferior tibiofibular ligament (PITFL) insertion, with syndesmosis disruption. Initial damage control included an external fixator.

View Article and Find Full Text PDF

A feature-based approach for atlas selection in automatic pelvic segmentation.

PLoS One

January 2025

Department of Radiation Physics, Zhejiang Key Laboratory of Radiation Oncology, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China.

Accurate and efficient automatic segmentation is essential for various clinical tasks such as radiotherapy treatment planning. However, atlas-based segmentation still faces challenges due to the lack of representative atlas dataset and the computational limitations of deformation algorithms. In this work, we have proposed an atlas selection procedure (subset atlas grouping approach, MAS-SAGA) which utilized both image similarity and volume features for selecting the best-fitting atlases for contour propagation.

View Article and Find Full Text PDF

This study aimed to evaluate the feasibility of VX2 tumor in rabbit auricles as an experimental model for intra-arterial embolization. This study was approved by our Institutional Animal Care and Use Committee. VX2 tumors were implanted in both auricles of 12 New Zealand White Rabbits.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!