Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Octamethylcyclotetrasiloxane (D4) and decamethylpentasiloxane (D5) are used as ingredients for personal care products (PCPs). Because of the use of these PCPs, consumers are exposed daily to D4 and D5. A sensitive analytical method was developed for analysis of D4 and D5 in end-exhaled air by thermal desorption gas chromatography mass spectrometry (TD-GC-MS), to determine the internal dose for consumer exposure assessment. Fifteen consumers provided end-exhaled air samples that were collected using Bio-VOC breath samplers and subsequently transferred to automatic thermal desorption (ATD) tubes. Prior to use, the ATD tubes were conditioned for a minimum of 4 h at 350 °C. The TD unit and auto sampler were coupled to a GC-MS using electron ionization. Calibration was performed using 0-10 ng/μL solutions of D4/D5 and (13)C-labeled D4/D5 as internal standards. The ions monitored were m/z 281 for D4, 355 for D5, 285 for (13)C-labeled D4, and 360 for (13)C-labeled D5. The addition of internal standard reduced the coefficient of variation from 30.8% to 9.5% for D4 and from 37.8% to 12.5% for D5. The limit of quantification was 2.1 ng/L end-exhaled air for D4 and 1.4 ng/L end-exhaled air for D5. With this method, cyclic siloxanes (D4 and D5) can be quantified in end-exhaled air at concentrations as low as background levels observed in the general population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac5004695 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!