Aim: Balloon aortic valvuloplasty (BAV) has reemerged with transcatheter valve therapy. Cylindrical balloons have been the device of choice despite limitations. An hour glass shaped balloon may permit enhanced fixation and broader leaflet opening without annular compromise.
Methods: We report our initial BAV experience using the V8 balloon (InterValve Inc.) in 20 consecutive patients compared to 20 patients from a 403-patient BAV database using cylindrical balloons. Patients were propensity matched on a 1:1 basis by age, gender, left ventricular ejection fraction (LVEF), baseline aortic valve area (AVA) and Society of Thoracic Surgery (STS) mortality risk score. End points included change in AVA and aortic insufficiency (AI) by echocardiography. New atrioventricular conduction defects (AVCD), need for post procedure pacemaker were documented. Major adverse events (MAE) included procedure related death, emergency surgery or stroke.
Results: V8 and cylindrical balloon groups were similar across age, gender, LVEF, AVA and STS score. The change in AVA from baseline to post-procedure strongly trended towards being larger in the V8 group than cylindrical balloon group (mean [SD]; 0.30±0.23 cm2 vs. 0.17±0.21 cm2; P=0.063). There were no differences in outcomes for degree of AI, AVCD, need for pacemaker or MAE.
Conclusion: Preliminary findings in this small experience suggest an advantage for enhancing AVA when using the V8 compared with cylindrical balloons. Additionally, there was no evidence of increased AI, AVCD or MAE.
Download full-text PDF |
Source |
---|
Protoplasma
January 2025
Department of Biology, Faculty of Science, Gazi University, Ankara, Turkey.
Copris are part of the Scarabaeidae family of Coleoptera. Copris are dung beetles or coprophagous beetles. These insects are called tunnelers because they excavate channels in the substrate.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Pre-Clinical Research Centre, Wrocław Medical University, Marcinkowskiego 1, 50-368 Wrocław, Poland.
Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.
View Article and Find Full Text PDFAnn Ital Chir
December 2024
Department of Urology, Liangping District People's Hospital, 405200 Chongqing, China.
Aim: To investigate the clinical efficacy of transurethral columnar balloon dilation of prostate (TUCBDP) in the treatment of small-volume benign prostatic hyperplasia (BPH) and provide the optimal treatment for the surgical treatment of small volume benign prostatic hyperplasia.
Methods: This retrospective study analyzed 106 patients with small-volume BPH who underwent surgical treatment at the Department of Urology, Xiangya Changde Hospital from December 2023 to January 2024. The patients were divided into two groups based on the type of surgery received: TUCBDP group (n = 53) and transurethral resection of prostate (TURP) group (n = 53), which serves as the control group.
NMC Case Rep J
December 2024
Department of Neurosurgery, Fukushima Medical University, Fukushima, Fukushima, Japan.
Although rare, penetrating cervical vascular injury poses significant challenges with a poor patient prognosis, often attributed to severe hemorrhage and accompanying injuries. We encountered a case of hemorrhagic shock resulting from a penetrating injury to the common carotid artery (CCA), which was successfully managed using a combination of endovascular therapy and direct surgical intervention. A 23-year-old man presented with a self-inflicted stab wound on the left side of his neck from a kitchen knife.
View Article and Find Full Text PDFAnn Biomed Eng
December 2024
Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, 20133, Milan, Italy.
Drug-coated balloons (DCBs) aim to deliver drug-loaded surface coating upon inflation at specific vascular sites, yet the role of inflation pressure remains to be defined. We implement a new approach combining ex vivo stamping experiments with in silico simulations to study acute coating transfer by commercial DCBs. This methodology comprises 3 essential pillars: (I) DCB resin inflation and slicing into cylindrical segments for subsequent stamping onto porcine-excised tissue, (II) Numerical inflation of a full DCB replica in an idealized porcine vessel to predict in vivo interfacial contact pressures (CPs) and subsequent interfacial-level numerical stamping to calculate appropriate benchtop forces that recreate these in vivo CP values, and (III) ex vivo stamping experiments and optical analysis of the stamped surfaces (DCB segment and arterial tissue), using a standard high-resolution camera to visualize coating.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!