Objectives: In systemic sclerosis (SSc), left ventricular diastolic dysfunction reflects primary myocardial involvement of the disease. We aimed to assess the abnormalities of the diastolic function, analyze the characteristics of the disease progression, and investigate the prognostic value of diastolic dysfunction in SSc patients.

Patients And Methods: A total of 34 SSc patients (57 ± 12 years, 31 female) were involved in the study. The following traditional or tissue Doppler parameters of left ventricular diastolic function were obtained: E/A, lateral E', E/E', left ventricular mass index (LVM index), and maximal left atrial (LA) volume index. Measurements were repeated after 5.5 years.

Results: At baseline, diastolic dysfunction was found in 62% of the SSc patients. Follow-up time was 5.4 ± 1.2 years. A total of 6 patients died of heart failure. In univariate Cox regression analysis, age (HR = 1.08, p < 0.05), LVM index (HR = 1.07, p < 0.01), lateral E' (HR = 1.57, p = 0.05), and LA volume index (HR = 1.11, p < 0.01) were predictors of survival. During the follow-up, significant increase in LA volume index (27.5 ± 9.7 vs. 35.4 ± 10.6 cm(3)/m(2), p < 0.001) and E/E' was found (7.6 ± 2.5 vs. 8.7 ± 3.8, p < 0.05) while E' did not change (9.6 ± 2.6 vs. 9.2 ± 1.9 cm/s, NS). The increase in LA volume index showed positive correlation (r = 0.46, p < 0.05) while the decrease in E' values showed negative correlation (r = -0.54, p < 0.01) with the duration of the SSc.

Conclusion: In SSc patients, left ventricular diastolic dysfunction is highly prevalent and is associated with increased risk of mortality. Our data suggest that in the advanced phase of the disease, the myocardial fibrotic processes burns out while the increase of the filling pressure progresses continuously.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.semarthrit.2014.04.001DOI Listing

Publication Analysis

Top Keywords

left ventricular
20
ventricular diastolic
16
diastolic dysfunction
16
diastolic function
12
ssc patients
12
systemic sclerosis
8
disease progression
8
increase volume
8
diastolic
7
left
6

Similar Publications

The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.

View Article and Find Full Text PDF

Left ventricular rigor mortis interferes with postmortem aortic root geometry.

Int J Legal Med

January 2025

Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.

Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.

View Article and Find Full Text PDF

Aims: Left ventricular (LV) diastolic dysfunction and heart failure with preserved ejection fraction (HFpEF) are common cardiac complications of patients with systemic sclerosis (SSc). Exercise stress echocardiography is often used in symptomatic patients with SSc to detect abnormal increases in pulmonary pressures during exercise, but the pathophysiologic and prognostic significance of exercise stress echocardiography to assess the presence of HFpEF in these patients is unclear.

Methods And Results: Patients with SSc (n=140) underwent ergometry exercise stress echocardiography with simultaneous expired gas analysis.

View Article and Find Full Text PDF

Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.

Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.

View Article and Find Full Text PDF

Pimobendan oral solution is bioequivalent to pimobendan chewable tablets in beagle dogs.

J Vet Intern Med

January 2025

Boehringer Ingelheim Pharma GmbH & Co., Ingelheim, Germany.

Background: Myxomatous mitral valve disease (MMVD) is frequently diagnosed in small breed dogs. Pimobendan oral solution has been developed to improve dosing accuracy in small and toy breed dogs.

Hypothesis/objectives: Demonstrate bioequivalence of pimobendan oral solution with pimobendan chewable tablets using a pharmacokinetic and a pharmacodynamic study in healthy purpose bred dogs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!