A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative assessment of midflexion laxity in total knee prosthesis. | LitMetric

Background: Soft-tissue balancing of the knee is fundamental to the success of a total knee arthroplasty (TKA). In posterior-stabilized TKA, there is no stabilizer of the anterior-posterior translation in the midflexion range in which the cam-post mechanism does not engage yet. Therefore, instability in the midflexion range is suspected to occur in posterior-stabilized TKA. The purpose of this study was to measure the joint gap throughout a full range of motion and to analyze the joint gap laxity in the midflexion range after implantation of a mobile-bearing posterior-stabilized total knee prosthesis.

Methods: Joint gap kinematics in 259 knees with varus osteoarthritis were measured during TKAs using a tensor device with the same shape of a total knee prosthesis of the same design was used. After the implantation of a mobile-bearing posterior-stabilized prosthesis and the reduction of the patellofemoral joint, the joint gap was measured at 0°, 30°, 60°, 90°, 120°, and 145° of flexion.

Results: The center size of the joint gap was tight in extension and deep flexion and loose at midflexion ranges, especially at 30° of flexion (p<0.001). The symmetry of the joint gap was varus at 0° and 145° of flexion (p<0.001).

Conclusions: Our results showed the joint gap laxity in the midflexion range after the implantation of a mobile-bearing posterior-stabilized prosthesis. Our new tensor device, which can attach the polyethylene insert trial, will provide the important information about the joint gap kinematics after implantation of total knee prostheses.

Level Of Evidence: IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2014.04.010DOI Listing

Publication Analysis

Top Keywords

joint gap
20
total knee
16
midflexion range
12
knee prosthesis
8
posterior-stabilized tka
8
implantation mobile-bearing
8
mobile-bearing posterior-stabilized
8
joint
6
midflexion
5
knee
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!