Two-point left ventricle pacing and cardiac computed tomography.

Case Rep Cardiol

Unit of Noninvasive Cardiovascular Diagnostics, Upper-Silesian Medical Centre, 40-635 Katowice, Poland ; 3rd Division of Cardiology, Medical University of Silesia, 40-752 Katowice, Poland.

Published: May 2014

AI Article Synopsis

  • Endocardial leads can create a lot of artifacts that complicate the visualization of coronary vessels during multislice computed tomography (MSCT).
  • Despite these challenges, the case study suggests that MSCT can still effectively visualize both coronary arteries and endocardial leads.
  • The findings indicate that it is feasible to conduct MSCT even when four endocardial leads are present.

Article Abstract

Endocardial leads can potentially cause problems during coronary vessels visualization in multislice computed tomography (MSCT) due to a large number of artifacts. Based on presented case, we conclude that it is possible to perform MSCT of coronary arteries and leads visualization despite coexistence of four endocardial leads.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007785PMC
http://dx.doi.org/10.1155/2012/347189DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
endocardial leads
8
two-point left
4
left ventricle
4
ventricle pacing
4
pacing cardiac
4
cardiac computed
4
tomography endocardial
4
leads problems
4
problems coronary
4

Similar Publications

Article Synopsis
  • Hyperacute cardiac CT is more effective than transthoracic echocardiography in detecting intracardiac thrombus, but its routine use is limited due to costs and risks.
  • A study of 1,136 ischemic stroke or TIA patients found that longer arterial input function (AIF) dispersal times correlate with the presence of thrombus and worse outcomes, with a specific cutoff of 33 seconds indicating higher risk.
  • The findings support using AIF dispersal measurements to help identify patients who may benefit from cardiac imaging, potentially optimizing resource use in stroke management.
View Article and Find Full Text PDF

Background: Computed tomography (CT)-derived low muscle mass is associated with adverse outcomes in critically ill patients. Muscle ultrasound is a promising strategy for quantitating muscle mass. We evaluated the association between baseline ultrasound rectus femoris cross-sectional area (RF-CSA) and intensive care unit (ICU) mortality.

View Article and Find Full Text PDF

Low-cost male urogenital simulator for penile implant surgery training: a 3D printing approach.

3D Print Med

January 2025

Department of Surgical & Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Background: Penile implant surgery is the standard surgical treatment for end-stage erectile dysfunction. However, the growing complexity of modern high-tech penile prostheses has increased the demand for more practical training opportunities. The most advanced contemporary training methods involve simulation training using cadavers, with costs exceeding $5,000 per cadaver, inclusive of biohazard fees.

View Article and Find Full Text PDF

To investigate if progression of coronary artery calcification (CAC) in patients with systemic lupus erythematosus (SLE) is associated with renal and traditional cardiovascular risk factors as well as incidence of myocardial infarctions. CAC progression was evaluated by cardiac computed tomography (CT) at baseline and after 5 years. Multivariable Poisson regression was applied to investigate associations between CAC progression and baseline values for traditional cardiovascular risk factors, CAC, SLE disease duration, lupus nephritis, and renal function.

View Article and Find Full Text PDF

Coronary artery calcification (CAC) is a key marker of coronary artery disease (CAD) but is often underreported in cancer patients undergoing non-gated CT or PET/CT scans. Traditional CAC assessment requires gated CT scans, leading to increased radiation exposure and the need for specialized personnel. This study aims to develop an artificial intelligence (AI) method to automatically detect CAC from non-gated, freely-breathing, low-dose CT images obtained from positron emission tomography/computed tomography scans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!