A novel electron beam focusing scheme for medical X-ray sources is described in this paper. Most vacuum based medical X-ray sources today employ a tungsten filament operated in temperature limited regime, with electrostatic focusing tabs for limited range beam optics. This paper presents the electron beam optics designed for the first distributed X-ray source in the world for Computed Tomography (CT) applications. This distributed source includes 32 electron beamlets in a common vacuum chamber, with 32 circular dispenser cathodes operated in space charge limited regime, where the initial circular beam is transformed into an elliptical beam before being collected at the anode. The electron beam optics designed and validated here are at the heart of the first Inverse Geometry CT system, with potential benefits in terms of improved image quality and dramatic X-ray dose reduction for the patient.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4008761PMC
http://dx.doi.org/10.1063/1.4872033DOI Listing

Publication Analysis

Top Keywords

electron beam
16
beam optics
12
beam focusing
8
medical x-ray
8
x-ray sources
8
limited regime
8
optics designed
8
beam
7
electron
5
x-ray
5

Similar Publications

Volume electron microscopy (vEM) enables biologists to visualize nanoscale 3D ultrastructure of entire eukaryotic cells and tissues prepared by heavy atom staining and plastic embedding. The highest resolution vEM technique is focused ion-beam scanning electron microscopy (FIB-SEM), which provides nearly isotropic (~5-10 nm) spatial resolution at fluences of > 10,000 e /nm . However, it is not clear how such high resolution is achievable because serial block-face (SBF) SEM, which incorporates an in-situ ultramicrotome instead of a Ga FIB beam, results in radiation-induced collapse of similar specimen blocks at fluences of only ~20 e /nm .

View Article and Find Full Text PDF

In this study, minced turkey meat samples were subjected to electron-beam irradiation with dosages of 0, 1.5, 3, and 5 kGy, and then microbial (mesophilic and psychrotrophic bacteria), physiochemical (pH, water activity [a], thiobarbituric acid reactive substances [TBARS], and peroxide value [PV]), and sensory (color, odor, texture, and overall acceptability) analyses were performed at 0 and 6 months of freezing storage (-18°C). Results showed that by 5 kGy irradiation and freezing treatments, the counts of psychrotrophic and mesophilic bacteria reduced remarkably ( < 0.

View Article and Find Full Text PDF

Efficient Data Sampling Scheme to Reduce Acquisition Time in Statistical ALCHEMI.

Microscopy (Oxf)

January 2025

Department of Materials Physics, Graduate School of Engineering, Nagoya University, Chikusa-ku, Nagoya 464-8603, Japan.

The distribution of dopants in host crystals significantly influences the chemical and electronic properties of materials. Therefore, determining this distribution is crucial for optimizing material performance. The previously developed statistical ALCHEMI (St-ALCHEMI), an extension of the atom-location by channeling-enhanced microanalysis (ALCHEMI) technique, utilizes variations in electron channeling based on the beam direction relative to the crystal orientation.

View Article and Find Full Text PDF

Multiexposure Grayscale Patterns with Low-Energy Electrons.

ACS Appl Mater Interfaces

January 2025

Zhejiang Key Laboratory of 3D Micro/Nano Fabrication and Characterization, School of Engineering, Westlake University, Hangzhou, Zhejiang 310030, China.

High-energy electron beam exposure is generally recognized as the standard for achieving high-precision nanofabrication. Low-energy electron beam exposure techniques offer advantages in 3D manufacturing; however, they have received limited attention in traditional processes due to precision limitations and insufficient exposure, leading to an underestimation of their potential. In this article, we introduce a nanofabrication strategy using low-energy electrons in ice-assisted electron-beam lithography (iEBL) alleviating the compatibility issue between resolution and quasi-3D manufacturing.

View Article and Find Full Text PDF

Objective: To investigate the reparative effect of hypoxia pretreated hAMSCs on radiation-induced damage to salivary gland function in mice.

Methods: hAMSCs were separated from human amniotic tissues by mechanical and enzymatic digestion methods and a 15 Gy electron beam was used to locally irradiate the neck of mouse to create a salivary gland injury model. The mouse models were randomly divided into four groups: control group, IR+PBS group, IR+Nor group and IR+HP group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!