Objectives: To investigate the role of volume quantitative assessment using multidetector-row computed tomography to select patients scheduled for endobronchial one-way valves treatment.
Methods: Twenty-five consecutive patients (15 with heterogeneous emphysema and 10 with giant emphysematous bulla) undergoing endobronchial valves treatment were enrolled. All patients were studied pre- and postoperatively with standard pulmonary functional tests and quantitative volume assessment of target lobe and entire lung. Emphysematous parenchyma was obtained applying density thresholds of -1.024/-950 Hounsfield units. Among different subtype of patients, we evaluated: (i) the differences between preoperative versus postoperative data; (ii) the correlation between functional and volumetric quantification changes and (iii) the critical threshold value of volumetric quantification of the target lobe in close association with clinical effects.
Results: Among heterogeneous emphysematous and giant emphysematous bulla patients, a significant improvement of flow-expiratory volume in 1 s (from 36.9 ± 15.3 to 43.9 ± 10.4; P = 0.01; and from 35.8 ± 6.0 to 47.5 ± 7.9; P < 0.0001, respectively); and of forced vital capacity (from 41.9 ± 5.9 to 47.3 ± 9.3; P = 0.0009 and from 40.7 ± 5.9 to 48.8 ± 4.9; P = 0.0002, respectively); and a significant reduction of residual volume (from 185 ± 14 to 157 ± 14.7; P = 0.005; and from 196 ± 13.5 to 137 ± 21; P < 0.0001, respectively) and of total lung volume (from 166.7 ± 13 to 137 ± 18 ; P = 0.0003, and from 169 ± 15 to 134 ± 18; P < 0.0001, respectively) were seen after treatment. The volumetric measurements showed a reduction of volume of the treated lobe among heterogeneous emphysematous patients (from 1448 ± 204 to 1076 ± 364; P = 0.0008); and in those with giant emphysematous bulla (from 1668 ± 140 to 864 ± 199; P < 0.0001). The entire lung and target lobe volume changes were inversely correlated with change in forced expiratory volume in 1 s in patients with heterogeneous emphysematous (r = -0.7; P = 0.0006; and r = -0.7; P = 0.0009, respectively) and giant emphysematous bulla (r = -0.8; P = 0.001; and r = -0.7; P = 0.009, respectively). Among patients with heterogenous emphysematous and giant emphysematous bulla, the value of sensitivity and specificity were 66.6 and 83%, respectively (for a volumetric qunatification >1.5239), and of 60 and 100%, respectively (for a volumetric qunatification >1.762).
Conclusions: Our study showed that the volumetric quantification adds further informations to the routine evaluation for optimizing the selection of patients scheduled for endobronchial valve treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/icvts/ivu107 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!