Background: Pleural manometry can predict the presence of trapped lung and guide large-volume thoracentesis. The current technique for pleural manometry transduces pressure from the needle or intercostal catheter, necessitating intermittent cessation of fluid drainage at the time of pressure recordings.
Objectives: To develop and validate a technique for performing continuous pleural manometry, where pressure is transduced from an epidural catheter that is passed through the drainage tube to sit within the pleural space.
Methods: Pleural manometry was performed on 10 patients undergoing thoracentesis of at least 500 ml, using the traditional intermittent and new continuous technique simultaneously, and pleural pressures were recorded after each drainage of 100 ml. The pleural elastance (PEL) curves and their 95% confidence intervals (CIs), derived using measurements from each technique, were compared using the analysis of covariance and Student's paired t test, respectively.
Results: There was no significant difference in PEL calculated using each method (p > 0.1); however, there was a trend towards the CI for the PEL derived from the continuous method being narrower (p = 0.08). Fully automated measurement of drainage volume and pleural pressure, with real-time calculation and display of PEL, was achieved by connecting the system to a urodynamics machine.
Conclusions: Pleural manometry can be transduced from an epidural catheter passed through the drainage tube into the pleural space, which gives continuous recording of the pleural pressure throughout the procedure. This allows for automated calculation and display of the pleural pressure and PEL in real time, if the system is connected to a computer with appropriate software.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000358842 | DOI Listing |
BMC Anesthesiol
November 2024
Dipartimento Area Emergenza Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
Background: Transpulmonary pressure is the effective pressure across the lung parenchyma and has been proposed as a guide for mechanical ventilation. The pleural pressure is challenging to directly measure in clinical setting and esophageal manometry using esophageal balloon catheters was suggested for estimation. However, the accuracy of using esophageal pressure to estimate pleural pressure is debated due to variability in the mechanical properties of respiratory system, esophagus and esophageal catheter.
View Article and Find Full Text PDFCrit Care
September 2024
Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, USA.
Background: The superimposed pressure is the primary determinant of the pleural pressure gradient. Obesity is associated with elevated end-expiratory esophageal pressure, regardless of lung disease severity, and the superimposed pressure might not be the only determinant of the pleural pressure gradient. The study aims to measure partitioned respiratory mechanics and superimposed pressure in a cohort of patients admitted to the ICU with and without class III obesity (BMI ≥ 40 kg/m), and to quantify the amount of thoracic adipose tissue and muscle through advanced imaging techniques.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
July 2024
Department of Interventional Radiology, University of Kansas Medical Center, 3901 Rainbow Blvd, Kansas City, KS, 66160, USA.
Purpose: To determine the safety and efficacy associated with drainage volumes greater than 1,500 mL in a single, unilateral thoracentesis without pleural manometry measurements.
Materials And Methods: This retrospective, single-institution study included 872 patients (18 years and older) who underwent ultrasound-guided thoracentesis. Patient and procedures data were collected including demographics, number of and laterality of thoracenteses, volume and consistency of fluid removed, and whether clinical or radiologic evidence of re-expansion pulmonary edema (REPE) developed within 24 h of thoracentesis.
Surg Today
December 2024
Department of Surgery and Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Purposes: Polyglycolic acid (PGA) sheets, fibrin glue, and staple line reinforcement are frequently used to prevent air leakage during lung resection. However, the optimal staple-line reinforcement method remains unclear.
Methods: Cranial lung lobes of pigs were used to evaluate different staple line reinforcement methods (n = 6).
Tunis Med
February 2023
Gastroenterology department , Charles Nicolle Hospital/ University of tunis ElManar, Faculty of Medecine of Tunis, Tunisia.
Introduction: Pseudoachalasia is a rare clinical condition, often caused by malignancy. Rarely, this entity can reveal the underlying neoplasia. To the best of our knowledge, we report the first case of pseudoachalasia revealing a metastatic signet-ring cell carcinoma of the non-ampullary duodenum.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!