Despite the clinical benefit of implantable cardioverter defibrillator (ICD), there is a high frequency of inappropriate ICD therapy associated with impaired quality of life, unwanted health care resource utilization, and adverse clinical outcome. Alternative strategies of ICD programming are needed to reduce the risk of inappropriate and "unnecessary" ICD therapies and to improve patient outcome. In this review, we provide an overview of the rate of inappropriate and appropriate ICD therapies in clinical trials and large registries as well as a review of current trials evaluating novel ICD programming to reduce inappropriate ICD therapy to avoid unnecessary ICD therapy. Based on recent studies including a large randomized trial, we recommend a simple programming approach involving high-rate device therapy beginning at 200 bpm with a 2.5 sec delay for it reduces inappropriate therapy, unnecessary therapy, and all-cause mortality in patients receiving ICD or CRT-D devices for primary prevention indications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11886-014-0496-1 | DOI Listing |
J Thorac Dis
December 2024
Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Background: The benefits of pulmonary rehabilitation (PR) for patients with idiopathic pulmonary fibrosis (IPF) have been limited to improving dyspnea, exercise capacity, and quality of life (QoL). This study aimed to assess the current status of PR and its effect on prognosis.
Methods: The Nationwide Korean Health Insurance Review and Assessment Service (HIRA) database was used in this study.
Adv Healthc Mater
January 2025
Precision Research Center for Refractory Diseases, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 201620, China.
The rational design of self-assembled compounds is crucial for the highly efficient development of carrier-free nanomedicines. Herein, based on computer-aided strategies, important physicochemical properties are identified to guide the rational design of self-assembled compounds. Then, the pharmacophore hybridization strategy is used to design self-assemble nanoparticles by preparing new chemical structures by combining pharmacophore groups of different bioactive compounds.
View Article and Find Full Text PDFJ Gambl Stud
January 2025
Department of Psychosocial Science, University of Bergen, P.O. box 7807, Bergen, 5020, Norway.
Rates of gambling disorder (GD) have been found to be higher among people receiving disability benefit, but few studies have investigated whether receiving disability benefit prospectively actually increases the risk of GD. The present study investigated whether those with a disability benefit had an increased risk of developing GD using a case-control design. The study sample was retrieved from the Norwegian Patient Registry (NPR, N = 5,131) and consisted of all adults in Norway (18 years and older) who had received a GD diagnosis (F63.
View Article and Find Full Text PDFJ Cancer Res Clin Oncol
January 2025
Medical Research Center, Binzhou Medical University Hospital, Binzhou, Shandong, 256600, P.R. China.
Purpose: Immune checkpoint blockades (ICBs) are promising, however they do not fit all types of tumor, such as those lack of tumor antigens. Induction of potent anti-tumor T cell immunity is critical for cancer therapy. In this study, we investigated the efficacy of immunotherapy via the immunogenic cell death (ICD) dying tumor cells in mouse models of lung metastasis and tumorigenesis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!