Production of particulates from transducer erosion: implications on food safety.

Ultrason Sonochem

CSIRO Division of Animal, Food and Health Sciences, 671 Sneydes Road, Werribee, Vic 3030, Australia. Electronic address:

Published: November 2014

AI Article Synopsis

  • The study explored how metallic particles form from erosion using different frequencies of ultrasound in water for various durations.
  • Transducers operating at lower frequencies produced significant amounts of metallic micron-sized particles, while higher frequencies generated fewer particles.
  • Despite some metal leaching into the water, the concentrations remained below safe drinking water limits, and further analysis of the particles was limited to two-dimensional characterization.

Article Abstract

The formation of metallic particulates from erosion was investigated by running a series of transducers at various frequencies in water. Two low frequency transducer sonotrodes were run for 7.5h at 18kHz and 20kHz. Three high frequency plates operating at megasonic frequencies of 0.4MHz, 1MHz, and 2MHz were run over a 7days period. Electrical conductivity and pH of the solution were measured before and after each run. A portion of the non-sonicated and treated water was partially evaporated to achieve an 80-fold concentration of particles and then sieved through nano-filters of 0.1μm, 0.05μm, and 0.01μm. An aliquot of the evaporated liquid was also completely dried on strips of carbon tape to determine the presence of finer particles post sieving. An aliquot was analyzed for detection of 11 trace elements by Inductively Coupled Plasma Mass Spectroscopy (ICPMS). The filters and carbon tapes were analyzed by FE-SEM imaging to track the presence of metals by EDS (Energy Dispersive Spectroscopy) and measure the particle size and approximate composition of individual particles detected. Light microscopy visualization was used to calculate the area occupied by the particles present in each filter and high resolution photography was used for visualization of sonotrode surfaces. The roughness of all transducers before and after sonication was tested through profilometry. No evidence of formation of nano-particles was found at any tested frequency. High amounts of metallic micron-sized particles at 18kHz and 20kHz formed within a day, while after 7day runs only a few metallic micro particles were detected above 0.4MHz. Erosion was corroborated by an increase in roughness in the 20kHz tip after ultrasound. The elemental analysis showed that metal leach occurred but values remained below accepted drinking water limits, even after excessively long exposure to ultrasound. With the proviso that the particles measured here were only characterized in two dimensions and could be nanoparticulate in terms of the third dimension, this research suggests that there are no serious health implications resulting from the formation of nanoparticles under the evaluation conditions. Therefore, high frequency transducer plates can be safely operated in direct contact with foods. However, due to significant production of metallic micro-particulates, redesign of lower frequency sonotrodes and reaction chambers is advised to enable operation in various food processing direct-contact applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultsonch.2014.04.005DOI Listing

Publication Analysis

Top Keywords

frequency transducer
8
18khz 20khz
8
high frequency
8
particles detected
8
particles
7
frequency
5
production particulates
4
particulates transducer
4
transducer erosion
4
erosion implications
4

Similar Publications

An esophageal stent integrated with wireless battery-free movable photodynamic-therapy unit for targeted tumor treatment.

Mater Today Bio

February 2025

Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, 610041, China.

Esophageal cancer is the eighth most common cancer worldwide and the sixth leading cause of cancer-related deaths. In this study, we propose a novel esophageal stent equipped with a wireless, battery-free, and movable photodynamic therapy (PDT) unit designed to treat esophageal tumors with flexibility, precision, and real-time control. This system integrates a PDT unit and an electrochemical pneumatic soft actuator into a conventional esophageal stent.

View Article and Find Full Text PDF

In the field of steady-state visual evoked potential (SSVEP), stimulus paradigms are regularly arranged or mimic the style of a keyboard with the same size. However, stimulation paradigms have important effects on the performance of SSVEP systems, which correlate with the electroencephalogram (EEG) signal amplitude and recognition accuracy. This paper provides MP dataset that was acquired using a 12-target BCI speller.

View Article and Find Full Text PDF

Recently, Organ-on-a-Chip (OoC) platforms have arisen as an increasingly relevant experimental tool for successfully replicating human physiology and disease. However, there is a lack of a standard technology to monitor the OoC parameters, especially in a non-invasive and label-free way. Photoacoustic (PA) systems can be considered an alternative and accurate assessment method for OoC platforms.

View Article and Find Full Text PDF

Dual-frequency ultrasonic oxidation of cyanobacterial toxins (MC-LR and MC-RR) at drinking water resources: Assessment of analytical methods and ultrasonic reactor configuration.

Ultrason Sonochem

December 2024

Ataturk University, Engineering Faculty, Environmental Engineering Department, Erzurum 25240, TÜRKİYE. Electronic address:

Ultrasonic oxidation provides the degradation of a wide range of water pollutants to the final products defined as carbon dioxide, short-chain organic acids, and inorganic ions, typically less toxic and favorable to biodegradation. In this study, it was investigated the application of novel ultrasonic reactor that allows the several combinations of low (20 kHz and 40 kHz) and high frequency ultrasonic piezoceramic transducer (578 kHz, 862 kHz and 1142 kHz) to degrade two main cyanobacterial toxins, Microcystin-RR (MC-RR) and Microcystin-LR (MC-LR). A plate transducer operating at different frequencies (40 kHz or 578 kHz/862 kHz/1142 kHz) was combined with a probe (20 kHz) as well as two plate transducers 40 kHz and 578 kHz/862 kHz/1142 kHz were combined to provide dual frequency ultrasonic reactor (DFUR).

View Article and Find Full Text PDF

Aims: Stroke is a major public health concern leading to high rates of death and disability worldwide, unfortunately with no effective treatment available for stroke recovery during the repair phase.

Methods: Photothrombotic stroke was induced in mice. Adeno-associated viruses (AAV) were microinjected into the peri-infarct cortex immediately after photothrombotic stroke.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!