Assessment of elastin deficit in a Marfan mouse aneurysm model using an elastin-specific magnetic resonance imaging contrast agent.

Circ Cardiovasc Imaging

From the Departments of Cardiothoracic Surgery (H.O., A.R.D., F.E., B.A.D., M.A., M.P.F.), Radiology (L.J.P.), and Pathology (A.J.C.), Stanford University, CA; Department of Cardiovascular Surgery, Jichi Medical University, Saitama Medical Center, Saitama, Japan (H.O., M.A., H.A.); Lantheus Medical Imaging, North Billerica, MA (D.C.O., R.R.C., S.P.R.); Agilent Technologies, Yarnton, Oxford, United Kingdom (M.M.); Departments of Radiology (G.K.) and Medical Informatics and Radiology (H.S.), Erasmus MC, Rotterdam, The Netherlands; and Division of Cardiovascular Medicine, Stanford University, CA (M.V.M.).

Published: July 2014

Background: Ascending aortic dissection and rupture remain a life-threatening complication in patients with Marfan syndrome. The extracellular matrix provides strength and elastic recoil to the aortic wall, thereby preventing radial expansion. We have previously shown that ascending aortic aneurysm formation in Marfan mice (Fbn1(C1039G/+)) is associated with decreased aortic wall elastogenesis and increased elastin breakdown. In this study, we test the feasibility of quantifying aortic wall elastin content using MRI with a gadolinium-based elastin-specific magnetic resonance contrast agent in Fbn1(C1039G/+) mice.

Methods And Results: Ascending aorta elastin content was measured in 32-week-old Fbn1(C1039G/+) mice and wild-type (n=9 and n=10, respectively) using 7-T MRI with a T1 mapping sequence. Significantly lower enhancement (ie, lower R1 values, where R1=1/T1) was detected post-elastin-specific magnetic resonance contrast agent in Fbn1(C1039G/+) compared with wild-type ascending aortas (1.15±0.07 versus 1.36±0.05; P<0.05). Post-elastin-specific magnetic resonance contrast agent R1 values correlated with ascending aortic wall gadolinium content directly measured by inductively coupled mass spectroscopy (P=0.006).

Conclusions: Herein, we demonstrate that MRI with elastin-specific magnetic resonance contrast agent accurately measures elastin bound gadolinium within the aortic wall and detects a decrease in aortic wall elastin in Marfan mice compared with wild-type controls. This approach has translational potential for noninvasively assessing aneurysm tissue changes and risk, as well as monitoring elastin content in response to therapeutic interventions.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.114.001658DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
12
contrast agent
12
aortic wall
12
elastin-specific magnetic
8
ascending aortic
8
elastin content
8
resonance contrast
8
agent fbn1c1039g/+
8
aortic
5
assessment elastin
4

Similar Publications

Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.

View Article and Find Full Text PDF

Reline, which is composed of choline chloride and urea in a molar ratio of 1:2, is the first and most extensively studied deep eutectic solvent (DES). In certain applications, reline is blended with organic solvents, dimethyl sulfoxide (DMSO) in most cases, to gain improved properties. Therefore, it is crucial to have a profound understanding of the impact of DMSO on the dynamics and structures of the species in the binary mixtures.

View Article and Find Full Text PDF

CNN is considered an efficient tool in brain image segmentation. However, neonatal brain images require specific methods due to their nature and structural differences from adult brain images. Hence, it is necessary to determine the optimal structure and parameters for these models to achieve the desired results.

View Article and Find Full Text PDF

Magnetic resonance imaging (MRI) is one of the most commonly used tools in neuroscience. However, it implies exposure to high noise levels. Exposure to noise can lead to temporary or permanent hearing loss, especially when the exposure is long and/or repeated.

View Article and Find Full Text PDF

Introduction: Diagnosing dementia remains challenging in low-income settings due to limited diagnostic options and the absence of definitive biomarkers. The use of brain MRI in the diagnosis of dementia is infrequent in Uganda, and even when it is used, subtle findings like mild regional atrophy are often overlooked, despite being crucial for imaging diagnosis.

Objective: The purpose of this study was to explore the perceptions and practices of imaging personnel and physicians regarding the use of brain MRI as a diagnostic approach for dementia in Uganda.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!