In addition to contact force (CF), catheter stability is considered to be an important factor in creating radiofrequency lesions.To evaluate the catheter stability during pulmonary vein isolation (PVI) using CF-sensing catheter.PVI was performed in 32 patients using a CF-sensing catheter. Operators were blinded to CF. The application was arbitrarily defined as a "visually unstable" point if the catheter moved ≥ 4 mm. Data were analyzed according to 6 predefined segments for the ipsilateral PVs. As a parameter of catheter stability, the standard deviation (SD) of CF and relative standard deviation (RSD = 100 × SD of CF /average CF) were introduced.A total of 932 RF applications with 426 visually unstable points (UP; 45.7%) and 506 stable points (SP; 54.3%) were analyzed. SD was significantly higher at UP (8.0 g versus 5.7 g, P < 0.001), and RSD was significantly higher at UP (43.7% versus 26.5%, P < 0.001). Higher RSD was associated with visual instability in all the segments of both PVs, however, higher SD of CF was not in all segments. At the antero-superior segment of the LPV, and the roof and posteroinferior segments of the RPV, the RSD values were over 50%, suggesting catheter instability.Catheter instability occurred in 45% of ablations during PVI and was predominantly located in the antero-superior segment of the LPV and postero-inferior segment of the RPV, which may result in incomplete lesion formation. RSD had significant correlation with visual catheter stability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1536/ihj.13-302 | DOI Listing |
J Mol Cell Cardiol Plus
March 2024
Department of Physiology, Cardiovascular Research Institute Maastricht (CARIM), University Maastricht, Maastricht, the Netherlands.
Introduction: Repetitive focal and rotational activation patterns are currently used as additional ablation targets for atrial fibrillation (AF). However, there is no evidence that all these detected targets are actual sources of AF. In this paper, we present an approach that detects and ranks AF activation patterns not only based on the degree of pattern repetitiveness but also on the extent to which they are able to entrain their vicinity.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy.
This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Ten custom-made 3D-printed vascular models were produced using computed tomography angiography (CTA) scans of ten patients diagnosed with PAD. CTA images were analyzed using Syngo.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
Guangdong Engineering Technology Research Center of Small Household Appliances Innovation Design and Manufacturing, School of Mechanical Engineering, Guangdong Ocean University, Zhanjiang 524088, China.
During the production of medical thin-walled tubes, a thin coating layer is required. This requirement reduces the cross-sectional clearance area of the straight section flow channel formed by the mandrel and the die, leading to excessive pressure of the polymer melt at the shaping section, elevated die pressure, and backflow of the material melt, all of which directly impact the quality of the coating layer. To address these issues, this study conducted a non-isothermal numerical simulation of coating models both with and without a shaping section.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
School of Chemistry and Chemical Engineering, Tianjin University of Technology, 391 Binshuixidao, Tianjin 300384, China.
Catheter-associated urinary tract infection (CAUTI) induced by rapid bacterial colonization and biofilm formation on urinary catheters is a key issue that urgently needs to be addressed. To prevent CAUTI, many contact-killing, non-leaching coatings have been developed for the surfaces of silicone catheters. However, due to the chemical inertness of the silicone substrate, most current coatings lack adhesion and are unstable under external forces.
View Article and Find Full Text PDFBMC Nephrol
January 2025
Division of Nephrology, Johns Hopkins School of Medicine, 1830 E Monument Street, Room 416, Baltimore, MD, 21287, USA.
Background: Urinalysis is a commonly performed test for the diagnosis and prognosis of kidney disease in hospitalized patients. It involves examining the chemical composition of the urine and microscopy to examine the cells and casts. In clinical settings, urinalysis is frequently delayed by several hours after sample collection and held at room temperature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!