Laparoscopic resection for hepatocellular carcinoma: comparison between Middle Eastern and Western experience.

Hepatobiliary Surg Nutr

1 Pôle Hépatodigestif, Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, Université de Strasbourg, Strasbourg, France ; 2 Service de Chirurgie Générale, Digestive et Endocrinienne, Hôpital Robert Debré, Centre Hospitalier Universitaire de Reims, Université de Reims Champagne-Ardenne, Reims, France ; 3 INSERM, Unit 1110, Université de Strasbourg, Strasbourg, France ; 4 Institut de Recherche sur les Cancers de l'Appareil Digestif (IRCAD)-Institut Hospitalo-Universitaire de Strasbourg (IHU Mix-Surg), Strasbourg, France.

Published: April 2014

Background: Laparoscopic liver resection (LLR) is growing in popularity, but the short- and long-term outcome of patients undergoing LLR for hepatocellular carcinoma (HCC) has not yet been established.

Methods: A literature search was performed using PubMed, Scopus, and Web of Science (WoS) from cited English and Chinese publications. Clinical and survival parameters were extracted. The search was last conducted in October 2013. After application of selective criteria, 24 remaining original studies with more than 15 patients were analyzed.

Results: In the Western experience, mean operative time was between 150 to 300 minutes, and mean blood loss ranged from 55 to 452 mL. Transfusion was required in all series, ranging from 2.8% to 50%. The conversion rate ranged from 5% to 19.4%. Three cases of death were reported. General morbidity rate ranged from 1.5% to 25%. Specific complications were divided into hemorrhage (2.4% to 25%), ascites (3.7% to 15.3%), and biliary collection (0.6% to 5%). Liver insufficiency was reported in two cases. Mean hospital stay ranged from 5.4 to 15 days. In all case-matched studies, LLR was statistically associated with a shorter hospital stay. The 5-year overall survival rate ranged from 55% to 70%. No trocar-site recurrence was observed. The recurrence rate ranged from 21.4% to 50%. Comparative studies did not demonstrate any significant difference in terms of recurrence between LLR and open liver resection (OLR). In the Middle Eastern experience, mean operative time ranged from 147 to 325 minutes, and mean blood loss ranged from 88 to 808 mL. Transfusion was required, ranging from 1.8% to 19.2%. The conversion rate ranged from 1.8% to 18.6%, and four series reported no conversion. There was no mortality. The main specific complication was ascites (1.7% to 26.6%). A biliary collection was reported in only two series (10.7% and 13.3%), and only one case of postoperative liver insufficiency was reported. Mean hospital stay ranged from 4 to 11.5 days. Statistically, three comparative studies reported a shorter postoperative hospital stay following LLR versus OLR. The 5-year overall survival rate ranged from 50% to 76.6%. Comparative studies did not demonstrate any significant difference in terms of overall survival and recurrence rate between LLR and OLR. No trocar-site recurrence was reported. The recurrence rate ranged from 26.9% to 45.5%, and two series reported no recurrence.

Conclusions: Laparoscopic surgery should be considered an acceptable alternative for the treatment of HCC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3999416PMC
http://dx.doi.org/10.3978/j.issn.2304-3881.2014.04.03DOI Listing

Publication Analysis

Top Keywords

rate ranged
28
hospital stay
16
ranged
12
recurrence rate
12
comparative studies
12
hepatocellular carcinoma
8
middle eastern
8
western experience
8
liver resection
8
experience operative
8

Similar Publications

This study investigates the ablation performance of Inconel 718, a nickel-based superalloy, and metal matrix polycrystalline diamond (MMPCD), a super composite, using a nano-second (ns) pulsed laser across a range of ablation conditions. Single trenches varying in energy fluence and scanning speeds were created, analyzing the experimental responses in terms of ablation rate and surface roughness. Using regression techniques, models were developed to understand these relationships.

View Article and Find Full Text PDF

The contributed absorber design in graphene addition with the displacement of three materials for resonator design in Aluminum (Al), the middle substrate position with Titanium nitride (TiN), and the ground layer deposition by Iron (Fe) respectively. For the absorption validation highlight, the best four absorption wavelengths (µm) of 0.29, 0.

View Article and Find Full Text PDF

The Tibetan Plateau is home to numerous glaciers that are important for freshwater supply and climate regulation. These glaciers, which are highly sensitive to climatic variations, serve as vital indicators of climate change. Understanding glacier-fed hydrological systems is essential for predicting water availability and formulating climate adaptation strategies.

View Article and Find Full Text PDF

A simple model of the rheological curve of HPAM solutions at different temperatures.

Sci Rep

December 2024

Laboratorio de Fluidodinámica, Facultad de Ingeniería, Universidad de Buenos Aires/CONICET, Paseo Colón 850 CABA, Buenos Aires, Argentina.

The oil and gas industry faces two significant challenges, including rising global temperatures and depletion of reserves. Enhanced recovery techniques such as polymer flooding have positioned themselves as an alternative that attracts international attention thanks to increased recovery factors with low emissions. However, existing physical models need further refinement to improve predictive accuracy and prevent design failures in polymer flooding projects.

View Article and Find Full Text PDF

Polymer electrolyte membrane water electrolyzers (PEMWEs) are a critical technology for efficient hydrogen production to decarbonize fuels and industrial feedstocks. To make hydrogen cost-effective, the overpotentials across the cell need to be decreased and platinum-group metal loading reduced. One overpotential that needs to be better understood is due to mass transport limitations from bubble formation within the porous transport layer (PTL) and anode catalyst layer (ACL), which can lead to a reduction in performance at typical operating current densities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!