Development and validation of a fast and simple multi-analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC-MS and one-point calibration.

Drug Test Anal

Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical, Pharmacology and Toxicology, Saarland University, D-66421, Homburg (Saar), Germany.

Published: May 2014

Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full-scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi-analyte full-scan GC-MS approach was developed and validated with liquid-liquid extraction and one-point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one-point calibration with calibrators stored for up to four weeks reduced workload and turn-around time to less than 1 h. In summary, the multi-analyte approach with simple liquid-liquid extraction, GC-MS identification, and quantification over fast one-point calibration could successfully be applied to proficiency tests and real case samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/dta.1555DOI Listing

Publication Analysis

Top Keywords

one-point calibration
16
emergency toxicology
12
quantification drugs
8
drugs relevant
8
relevant emergency
8
chromatography-mass spectrometry
8
liquid-liquid extraction
8
quantification
6
development validation
4
validation fast
4

Similar Publications

Erlenmeyer shake flasks are widely used during the first steps of bioprocess development. Despite their broad application in academia and industry, shake flasks usually lack standardized and user-friendly online monitoring techniques. In this work, the pH and Respiratory Activity MOnitoring System (pH-RAMOS) for the non-invasive online measurement of the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and pH in up to eight parallel shake flasks under sterile conditions is presented.

View Article and Find Full Text PDF

We sought to develop and validate a new risk stratification score for mortality for children supported with a ventricular assist device (VAD). This retrospective, multicenter study used data from patients undergoing VAD implantation between April 2018 and February 2023 at 44 participating institutions in the Advanced Cardiac Therapies Improving Outcomes (ACTION) network. Multivariable Cox proportional-hazards modeled mortality after VAD implantation.

View Article and Find Full Text PDF

Isotope dilution with isotopically labeled biomass: An effective alternative for quantitative metabolomics.

Anal Chim Acta

August 2024

University of Vienna, Faculty of Chemistry, Institute of Analytical Chemistry, Waehringer Str. 38, 1090, Vienna, Austria; Vienna Metabolomics Center (VIME), University of Vienna, Althanstr. 14, 1090, Vienna, Austria; Chemistry Meets Biology, University of Vienna, Althanstr. 14, 1090, Vienna, Austria. Electronic address:

Background: State-of-the-art quantitative metabolomics relies on isotope dilution using internal standards (IS) derived from fully C labeled biomass. By spiking samples and external standards with known amounts of IS, the spike characterization demands are kept to a minimum. In fact, it is sufficient to experimentally assess the isotopic enrichment of the IS.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to validate the Japanese below-the-knee (J-BTK) chronic total occlusion (CTO) score as a predictor for successful guidewire crossing (S-GC) in patients undergoing endovascular therapy.
  • Conducted at 16 medical centers, the study included 751 BTK CTOs in 497 patients, categorizing them based on their S-GC outcomes using a scoring system that assesses factors like entry type, calcification, vessel diameter, CTO length, and target vessel outflow.
  • Results showed that higher J-BTK CTO scores correlated with lower S-GC success rates, and a modified version of the score, which included points for de novo lesions, further improved prediction accuracy for the likelihood
View Article and Find Full Text PDF

Fast neonicotinoid quantification in honey using the one-point internal calibration approach.

Food Chem X

October 2024

Neuchâtel Platform of Analytical Chemistry (NPAC), University of Neuchâtel, Avenue de Bellevaux 51, 2000 Neuchâtel, Switzerland.

Neonicotinoids, a highly effective class of insecticides used worldwide, have been identified as a major cause of concern for biodiversity. To assess the ecological and environmental consequences of neonicotinoids' use, reliable analytical methodologies, including calibration approaches, are needed. Here, we compared the performance of internal calibration (IC) using a single concentration of stable isotope-labeled standard (SIL) with classical multipoint external calibration (EC) for the quantification of six neonicotinoids in honey.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!