In this work, the characterization of the species produced in reactive plasmas by differentially pumped mass spectrometry is addressed. A H2/CH4/N2 mixture (90 : 5 : 5) was fed into a direct current glow discharge and analysed by conventional and cryo-trap assisted mass spectrometry. The gaseous mixture was chosen because of its particular relevance in the inhibition of tritium-rich carbon film deposition in fusion plasmas (scavenger technique) and in the deposition of amorphous hydrogenated carbon films by plasma-assisted chemical vapour deposition. Important changes in the composition of the detected species upon surface modification of the reactor walls (stainless steel or covered by an amorphous hydrogenated carbon layer) or in the way they are sampled (length and spatial configuration of the stainless steel duct) were detected. They are analysed in terms of radical formation and recombination on the reactor walls or into the sampling duct, thus providing some insight into the underlying chemistry. In general, when the reactor walls are covered by an amorphous hydrogenated carbon layer, more hydrocarbons are produced, but the radical production is lower and seem to be less reactive than in stainless steel. Also, two sources of oxygen contamination in the plasma have been identified, from the native oxide layer in stainless steel and from unintended water contamination in the chamber, which modify considerably the detected species.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jms.3346DOI Listing

Publication Analysis

Top Keywords

stainless steel
16
mass spectrometry
12
amorphous hydrogenated
12
hydrogenated carbon
12
reactor walls
12
differentially pumped
8
pumped mass
8
detected species
8
covered amorphous
8
carbon layer
8

Similar Publications

Cold atmospheric plasma (CAP) has emerged as a promising technology for neutralizing microbes, including multidrug-resistant strains. This study investigates CAP's potential as an alternative to traditional antimicrobial drugs for microbial inactivation. In the era of increasing antimicrobial resistance, there is a persistent need for alternative antimicrobial strategies.

View Article and Find Full Text PDF

Harmless and efficient nickel enrichment from nickel-containing waste slag using vitrification technology.

Environ Sci Pollut Res Int

January 2025

Qingdao Qingli Environmental Protectionquipmen Co, LTD, Jiaozhou, 266300, China.

With the growing demand for nickel in the stainless steel and battery industries, conventional methods of extracting nickel from ores face challenges such as high production costs and environmental concerns. This study proposes a new process for the recovery of nickel metal and the production of nickel-iron alloys from nickel-bearing scrap. The reduction rates of nickel and iron oxides were investigated by optimizing the roasting temperature, time, and C/O ratio, and the process was optimized using response surface methodology (RSM).

View Article and Find Full Text PDF

Manufacturing of Liposomes Using a Stainless-Steel Microfluidic Device: An Investigation into Design of Experiments.

Langmuir

January 2025

Department of Polymer and Materials Chemistry, Faculty of Chemistry & Petroleum Sciences, Shahid Beheshti University, P.O. Box 1983969411 Tehran, Iran.

Liposomes are highly beneficial nanocarrier systems due to their biocompatibility, low toxicity, and exceptional inclusiveness, which lead to improved drug bioavailability. For biological applications, accurate control over these nanoparticles' mean size and size distribution is essential. Micromixers facilitate the continuous production of liposomes, enhancing the precision of size regulation and reproducibility.

View Article and Find Full Text PDF

One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.

View Article and Find Full Text PDF

The aging population necessitates a critical need for medical devices, where polymers-based surface lubrication coating is essential for optimal functionality. In fact, lubrication and mechanical requirements vary depending on the service environment of different medical devices. Until now, key mean is still blank for general preparation of hydrophilic polymers-based lubrication coatings with on-demand mechanics and lubricity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!