A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A robust ISFET pH-measuring front-end for chemical reaction monitoring. | LitMetric

This paper presents a robust, low-power and compact ion-sensitive field-effect transistor (ISFET) sensing front-end for pH reaction monitoring using unmodified CMOS. Robustness is achieved by overcoming problems of DC offset due to trapped charge and transcoductance reduction due to capacitive division, which commonly exist with implementation of ISFETs in CMOS. Through direct feedback to the floating gate and a low-leakage switching scheme, all the unwanted factors are eliminated while the output is capable of tracking a pH reaction which occurs at the sensing surface. This is confirmed through measured results of multiple devices of different sensing areas, achieving a mean amplification of 1.28 over all fabricated devices and pH sensitivity of 42.1 mV/pH. The front-end is also capable of compensating for accumulated drift using the designed switching scheme by resetting the floating gate voltage. The circuit has been implemented in a commercially-available 0.35 μm CMOS technology achieving a combined chemical and electrical output RMS noise of 3.1 mV at a power consumption of 848.1 nW which is capable of detecting pH changes as small as 0.06 pH.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBCAS.2014.2313512DOI Listing

Publication Analysis

Top Keywords

reaction monitoring
8
floating gate
8
switching scheme
8
robust isfet
4
isfet ph-measuring
4
ph-measuring front-end
4
front-end chemical
4
chemical reaction
4
monitoring paper
4
paper presents
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!