In modern ultrasound imaging devices, two-dimensional probes and electronic scanning allow volumetric imaging of anatomical structures. When dealing with the design of such complex 3-D ultrasound (US) systems, as the number of transducers and channels dramatically increases, new challenges concerning the integration of electronics and the implementation of smart micro-beamforming strategies arise. Hence, the possibility to predict the behavior of the whole system is mandatory. In this paper, we propose and describe an advanced simulation tool for ultrasound system modeling and simulation, which conjugates the US propagation and scattering, signal transduction, electronic signal conditioning, and beamforming in a single environment. In particular, we present the architecture and model of an existing 16-channel integrated receiver, which includes an amplification and micro-beamforming stage, and validate it by comparison with circuit simulations. The developed model is then used in conjunction with the transducer and US field models to perform a system simulation, aimed at estimating the performance of an example 3-D US imaging system that uses a capacitive micromachined ultrasonic transducer (CMUT) 2-D phased-array coupled to the modeled reception front-end. Results of point spread function (PSF) calculations, as well as synthetic imaging of a virtual phantom, show that this tool is actually able to model the complete US image reconstruction process, and that it could be used to quickly provide valuable system-level feedback for an optimized tuning of electronic design parameters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2014.6805693 | DOI Listing |
Pak J Med Sci
January 2025
Engin Ersin Simsek Associate Professor Family Medicine, University of Health Sciences, Kartal Dr. Lütfi Kirdar City Hospital, Istanbul, Turkey.
Objective: In this study, it was aimed to screen fatty liver in individuals with metabolic disorders, and to investigate the use of some anthropometric calculations and body composition indices in demonstrating fatty liver disease.
Methods: The cross-sectional study included 224 participants with metabolic diseases. Anthropometric measurements of the participants were measured.
Pak J Med Sci
January 2025
Muhammad Ashfaq, MCPS, FCPS, CHPE (JSMU) Pediatric Medicine, National Institute of Child Health Karachi, Pakistan.
Objectives: To determine gender and ethnic distribution of developmental dysplasia of hip in newborns using Graf method for ultrasound. To determine the significance of association between developmental dysplasia of hip with ethnicity in newborns using Graf's method ultrasound.
Method: This analytical cross-sectional observational study was conducted in Karachi from January through June 2022 .
J Pain Res
January 2025
Department of General Surgery, The 955th Hospital of Chinese People's Liberation Army, Tibet, 854000, People's Republic of China.
Fracture surgeries are frequently accompanied by severe pain, necessitating efficacious pain management strategies to enhance postoperative recovery. Nerve block techniques, which are critical in mitigating pain, involve the targeted administration of local anesthetics to disrupt nerve signal transmission, thereby achieving significant analgesia. Traditionally, these techniques rely on anatomical landmarks and the clinician's expertise, which can introduce variability and potential risks.
View Article and Find Full Text PDFCureus
January 2025
Internal Medicine, Hospital Senhora da Oliveira, Guimarães, PRT.
Sarcoidosis is a multisystem granulomatous disease of unknown etiology. Despite primarily affecting the lung, sarcoidosis can affect any organ, resulting in various clinical manifestations. We present a case of a 56-year-old man who developed thoracic pain over several months along with skin lesions.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
University Eye Clinic Maastricht, Maastricht, the Netherlands.
Purpose: This study aims to explore the diagnostic utility of ultrasound B-scan while introducing the "Triangle" sign as a novel indicator. It also validates the sign's efficacy in distinguishing between choroidal detachment (CD) and suprachoroidal hemorrhage (SCH) from retinal detachment (RD) and vitreous hemorrhage (VH).
Patients And Methods: Retrospective analysis of consecutive cases of total CD and SCH undergoing B-scan at a single tertiary imaging center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!