A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Element analysis of small and even smaller objects by ICPMS and LA-ICPMS. | LitMetric

Element analysis of small and even smaller objects by ICPMS and LA-ICPMS.

Chimia (Aarau)

ETH Zurich, Department of Chemistry, Vladimir-Prelog-Weg 1, CH-8093 Zurich, Switzerland.

Published: June 2014

Inductively coupled plasma mass spectrometry is increasingly used for non-traditional applications such as the analysis of solids at high spatial resolution when combined with laser ablation or the analysis of engineered nanoparticles. This report highlights recent projects and discusses the potentials and limitations these techniques offer. High-resolution laser ablation instrumentation allows element imaging at the μm-scale and can, therefore, be applied to, e.g., the mapping of metal isotope-labeled antibodies in biological tissues. Despite these advancements, the quantitative analysis of laser-produced aerosols is still a major concern. Here, the accuracy of analysis was found to strongly depend on particle size distribution but also on the morphology and composition of particles. In order to achieve a controlled supply of nanoparticles for analysis by inductively coupled plasma mass spectrometry, a dedicated microdroplet injection system was developed and characterized. This system allows a reproducible injection of single nanoparticles together with internal standards to determine their mass and composition.

Download full-text PDF

Source
http://dx.doi.org/10.2533/chimia.2014.112DOI Listing

Publication Analysis

Top Keywords

inductively coupled
8
coupled plasma
8
plasma mass
8
mass spectrometry
8
laser ablation
8
analysis
5
element analysis
4
analysis small
4
small smaller
4
smaller objects
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!