Aims: To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES).

Methods And Results: The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine months of follow-up, while a select subgroup also underwent optical coherence tomography (OCT). The primary efficacy hypothesis was superiority of in-stent late lumen loss (LLL) of APSES compared to ZES. At nine months, the primary endpoint was met, with a mean in-stent LLL of 0.27±0.46 mm in 103 APSES patients versus 0.58±0.41 mm in 52 ZES patients (p<0.001). The proportion of uncovered stent struts by OCT at nine months was very low in both groups. The mean neointimal thickness of covered struts (p=0.002) and percent net volume obstruction (p≤0.003) were significantly lower in the APSES than in the ZES group. Major adverse cardiac event and stent thrombosis rates were low and comparable between groups.

Conclusions: The DESSOLVE II trial demonstrated superiority in the primary efficacy endpoint of nine-month mean LLL for APSES compared to ZES. Strut coverage by OCT was high with both stents and the clinical safety endpoints including stent thrombosis were equally low in both groups. ClinicalTrials.gov Identifier: NCT01294748.

Download full-text PDF

Source
http://dx.doi.org/10.4244/EIJY14M05_03DOI Listing

Publication Analysis

Top Keywords

sirolimus-eluting stent
8
randomised study
4
study bioabsorbable
4
bioabsorbable polymer-coated
4
polymer-coated sirolimus-eluting
4
stent
4
stent dessolve
4
dessolve trial
4
trial aims
4
aims compare
4

Similar Publications

Background: First-generation bioresorbable scaffolds (BRS) increased risks of stent thrombosis and adverse events. The Bioheart scaffold is a new poly-L-lactic acid-based BRS.

Objectives: This study sought to evaluate the efficacy and safety of the BRS in patients with coronary artery disease.

View Article and Find Full Text PDF

Introduction And Objectives: Patients undergoing percutaneous coronary intervention in vessels with moderate-to-severe tortuosity are at higher risk of adverse outcomes, but data are scarce in the era of newer-generation stents. We compared outcomes following percutaneous coronary intervention in vessels with moderate-to-severe tortuosity using a bioresorbable-polymer sirolimus-eluting stent (BP-SES) vs a durable-polymer everolimus-eluting stent.

Methods: A total of 2350 patients from the BIOFLOW II, IV, and V randomized trials were stratified into 2 groups based on target-vessel tortuosity: none-to-mild and moderate-to-severe.

View Article and Find Full Text PDF

Limited evidence exists regarding the long-term outcomes of true versus nontrue coronary bifurcation lesions (CBLs) treated with current-generation drug-eluting stents and intravascular imaging guidance. The Sapporo Cardiovascular Clinic (SCVC) registry was a prospective, single-center, all-comers registry enrolling 1,727 consecutive patients treated with bioresorbable polymer sirolimus-eluting stent under complete imaging guidance. From this registry, 440 patients with CBLs (25.

View Article and Find Full Text PDF

Background: This study evaluated the safety and efficacy of BioMime sirolimus-eluting stent (SES) system, with an ultra-low strut thickness (65 µm), in real-world all-comers population with coronary artery stenosis (CAD).

Methods: This was a post-marketing, multicenter, single-arm, observational clinical registry among patients undergoing intervention for CAD. Patients were clinically followed up at 1, 9, 12, and 24 months after the index percutaneous coronary intervention.

View Article and Find Full Text PDF

Background: The Orsiro and Genoss DES stents are biodegradable polymer drug-eluting stents (DESs) with ultrathin struts.

Objective: To investigate the safety and efficacy of these two ultrathin DESs in real-world practice.

Methods: From a single-center prospective registry, we included 751 and 931 patients treated with the Genoss DES and Orsiro stents, respectively.

View Article and Find Full Text PDF