Purpose. To compare the corneal biomechanical properties of keratoconic patients and age-matched controls using corneal visualization Scheimpflug technology (Corvis ST). Methods. Sixty keratoconic eyes from 47 keratoconus patients and 60 normal eyes from 60 controls were enrolled in this prospective study. Tomography and biomechanical parameters of all eyes were obtained with the Pentacam and Corvis ST, respectively. Intraocular pressure was measured using a Goldmann applanation tonometer. Results. The tomography and biomechanical parameters of the keratoconic corneas were significantly different from those of the normal corneas except for the anterior chamber angle, first applanation length, the highest concavity time, and peak distance. The deformation amplitude was the best predictive parameter (area under the curve: 0.882), with a sensitivity of 81.7%, although there was a significant overlap between keratoconic and normal corneas that ranged from 1.0 to 1.4 mm. In both the keratoconus and control groups, the deformation amplitude was negatively correlated with intraocular pressure, central corneal thickness, and corneal volume at 3 and 5 mm. Conclusions. Corvis ST offers an alternative method for measuring corneal biomechanical properties. The possibility of classifying keratoconus based on deformation amplitude deserves clinical attention.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3988970PMC
http://dx.doi.org/10.1155/2014/147516DOI Listing

Publication Analysis

Top Keywords

corneal biomechanical
12
deformation amplitude
12
corneal visualization
8
visualization scheimpflug
8
scheimpflug technology
8
keratoconic normal
8
normal eyes
8
biomechanical properties
8
tomography biomechanical
8
biomechanical parameters
8

Similar Publications

Purpose: The distinction between pellucid-like keratoconus (PLK) and pellucid marginal corneal degeneration (PMD) based on tomographic examinations is difficult. In this study, corneal tomographic and biomechanical parameters, after classifying PMD and PLK using swept-source optical coherence tomography, were analyzed.

Methods: Diagnoses of PLK and PMD were made using SS-OCT imaging, two groups were formed: PLK (n = 30) and PMD (n = 10).

View Article and Find Full Text PDF

Inducing cylindrical and spherical defocus after implantation with new generation intraocular lenses improves intermediate and near visual acuity.

Sci Rep

December 2024

Imaging, Biomechanics and Mathematical Modelling Solutions Lab, Narayana Nethralaya Foundation, Bangalore, India.

An induced cylinder and spherical power after implantation with an extended depth of focus (EDOF) and enhanced monofocal intraocular lens (IOL) could improve distance, intermediate (60 cm) and near (40 cm) visual acuity (VA). In this prospective study, forty eyes with Eyhance EDOF IOL (Johnson and Johnson, USA) and 40 eyes with Vivity EDOF IOL (Alcon Laboratories Inc. USA) were included.

View Article and Find Full Text PDF

Evidence for spinal disinhibition as a pain-generating mechanism in fibromyalgia syndrome.

Pain Rep

February 2025

Pain Research Institute, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, United Kingdom.

Introduction: Pain phenomenology in patients with fibromyalgia syndrome (FMS) shows considerable overlap with neuropathic pain. Altered neural processing leading to symptoms of neuropathic pain can occur at the level of the spinal cord, and 1 potential mechanism is spinal disinhibition. A biomarker of spinal disinhibition is impaired H-reflex rate-dependent depression (HRDD).

View Article and Find Full Text PDF

Analyzing the effect of surgical and corneal parameters on the postoperative refractive outcomes of SMILE in myopic eyes based on machine learning.

Am J Ophthalmol

December 2024

Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; School of Medicine, Nankai University, Tianjin, China; Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Ophthalmology Hospital, Tianjin, China; Nankai Eye Institute, Nankai University, Tianjin, China. Electronic address:

Purpose: To analyze the effect of individual parameters on the postoperative refractive outcomes of small incision lenticule extraction in myopic eyes using machine learning methods.

Design: Retrospective Clinical Cohort Study METHODS: We included 477 patients (922 eyes) of small incision lenticule extraction at Tianjin Ophthalmology Hospital and divided the patients into two groups to analyzed the factors affecting postoperative refractive outcomes based on the label of postoperative spherical equivalent (SE) ≤ -0.50D.

View Article and Find Full Text PDF

Expression of Yes-associated protein in endothelial cells of human corneas before and after storage in organ culture.

Sci Rep

December 2024

Laboratory of Biology, Engineering, and Imaging for Ophthalmology, BiiO, Faculty of Medicine, University of Jean Monnet, 10 rue de la Marandière, 42270, Saint-Priest en Jarez, France.

The cornea, the anterior meniscus-shaped transparent and refractive structure of the eyeball, is the first mechanical barrier of the eye. Its functionality heavily relies on the health of its endothelium, its most posterior layer. The treatment of corneal endothelial cells (CECs) deficiency is allogeneic corneal graft using stored donor corneas.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!