Besides several side effects including anaphylaxis, blue dyes are also known to cause false pulse oximeter readings. We aimed to examine the effects of subareolar isosulfan blue injection on pulse oximeter (SpO2) readings. The study group included 27 patients undergoing SLNB using both radiocolloid and isosulfan blue. Another group of 27 patients constituted the control group. Pulse oximeter readings were compared. SpO2 decline ≥4 % was defined as significant. All but one (96.2 %) of the patients in the study group showed SpO2 declines, compared to only one patient in the control group. Median ± Interqartile Range (IR) SpO2 decrease was 3.0 ± 4.0 % in the study and 0.0 ± 1.0 % in the control group (p < 0.001). There were significant (≥4 %) SpO2 decreases in 13 (48.1 %) patients in the study group. Statistically significant differences were noted between the two groups in all recordings between 15 and 180 min (p < 0.001). Initial time for SpO2 fall and the time to the lowest SpO2 recording were 10.0 ± 10.0 and 40.0 ± 30.0 min respectively. Using subareolar injection, the frequency of false readings is comparable with intraparenchymal injections, and is higher than intradermal injections. Time to peak SpO2 fall, and the recovery period, are delayed in the subareolar technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4006001PMC
http://dx.doi.org/10.1007/s12262-012-0624-3DOI Listing

Publication Analysis

Top Keywords

pulse oximeter
16
isosulfan blue
12
oximeter readings
12
control group
12
subareolar isosulfan
8
blue injection
8
injection pulse
8
study group
8
group
6
blue
4

Similar Publications

Correlation between oxygen reserve index monitoring and blood gas oxygen values during anesthesia in robotic total prostatectomy surgery.

BMC Anesthesiol

January 2025

Department of Anesthesiology and Reanimation, University of Health Sciences, Gulhane Training and Research Hospital, Etlik, Ankara, 06010, Turkey.

Introduction-objective: Hyperoxia is associated with acute lung injury and atelectasis. Arterial blood gas measurement is an invasive method. The Oxygen Reserve Index (ORI) was developed to monitor the oxygen values of patients.

View Article and Find Full Text PDF

Background: Pain management in pediatric patients during dental procedures is very important. Here, the traditional method of behavior management is compared with novel methods.

Aim: To compare and determine the effectiveness of an external cooling and vibrating device vs counterstimulation with the conventional technique in reducing the fear and discomfort of pediatric dental patients aged 5-7 years during inferior alveolar nerve block (IANB).

View Article and Find Full Text PDF

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO measurement in consumer wearables that utilise reflectance pulse oximeters.

View Article and Find Full Text PDF

The effect of skin pigmentation on photoplethysmography and, specifically, pulse oximetry has recently received a significant amount of attention amongst researchers, especially since the COVID-19 pandemic. With most computational studies observing overestimation of arterial oxygen saturation (SpO) in individuals with darker skin, this study seeks to further investigate the root causes of these discrepancies. This study analysed intensity changes from Monte Carlo-simulated reflectance PPG signals across light, moderate, and dark skin types at oxygen saturations of 70% and 100% in MATLAB R2024a.

View Article and Find Full Text PDF

Pulse oximetry at two sensor placement sites in conscious foals.

Acta Vet Scand

January 2025

Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Viikintie 49, 00014, Helsinki, Finland.

Background: Pulse oximetry has not been thoroughly evaluated for assessment of oxygenation in conscious foals. Compared with invasive arterial blood sampling, it is a painless and non-invasive method for real-time monitoring of blood oxygen saturation. The aim of this prospective clinical study was to evaluate the usability, validity, and reliability of pulse oximetry at two measuring sites (lip and caudal abdominal skin fold) for blood oxygen saturation measurement in conscious foals with and without respiratory compromise.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!