Purpose: To describe the use, tolerability, and efficacy of episcleral silicone matrix cyclosporine (ESMC) implants in dogs with keratoconjunctivitis sicca (KCS).
Methods: Retrospective study. ESMC implants (1.9 cm length, 30% wt/wt CsA in silicone; with approximately 12 mg of CsA loaded into them) were used in dogs with KCS responsive to topical CsA (good candidate, GC) or not responsive (poor candidate, PC). Ocular surface inflammation scores, Schirmer tear test (STT) values, and ocular discharge quantity were evaluated and compared.
Results: Twenty-seven eyes (15 dogs) received an ESMC implant for KCS; 15 eyes were considered GC, and 12 were considered PC. Both GC eyes and PC eyes showed a significant increase in STT values (increase of 7.7 and 8.5 mm/min; P = 0.023 and P = 0.003, respectively) after placement of ESMC implants (mean follow-up 18 ± 2 and 10.4 ± 15 months, respectively). Clinical signs improved significantly in both groups during the same follow-up, with reduction in conjunctival hyperemia (P < 0.001), corneal neovascularization (P = 0.004), corneal opacity (P = 0.003), and ocular discharge (P = 0.002). ESMC implants were well tolerated by all dogs, but two eyes lost the device at 12-months and 1-week follow-up, respectively.
Conclusions: Results from this study suggest that the EMSC implants were well tolerated and efficacious in dogs with KCS responsive to topical CsA as well as dogs with poor response to topical therapy. Further study is needed to determine the duration of efficacy and optimal dose of CsA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vop.12173 | DOI Listing |
Vet Ophthalmol
May 2015
Department of Veterinary Science and Public Health, Faculty of Veterinary Medicine, University of Milan, Milan, Italy.
Purpose: To describe the use, tolerability, and efficacy of episcleral silicone matrix cyclosporine (ESMC) implants in dogs with keratoconjunctivitis sicca (KCS).
Methods: Retrospective study. ESMC implants (1.
Vet Ophthalmol
July 2014
Department of Clinical Sciences, North Carolina State University, 1060 William Moore Drive, Raleigh, NC, 27607, USA.
Purpose: To describe the use of episcleral silicone matrix cyclosporine (ESMC) drug delivery devices in horses with immune-mediated keratitis (IMMK) with evaluation of tolerability and efficacy in long-term control of inflammation.
Methods: Retrospective study. ESMC implants (1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!