Background: Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint arthrodesis.
Methods: First metatarsophalangeal joint arthrodesis using a crossed screw technique was performed on 11 paired, preserved cadaver first rays with two 4.0-mm triple-threaded, cannulated headless screws or two 4.0-mm partially threaded, cannulated lag screws. The constructs were tested to failure through dorsally directed cantilever bending.
Results: The triple-threaded, cannulated headless screws displayed significantly greater bending stiffness (p=0.017) and failure load (p=0.040) during load-to-failure testing compared to the partially threaded, cannulated lag screws.
Conclusions: Triple-threaded, cannulated headless screws may be a viable alternative to partially threaded lag screws in first metatarsophalangeal arthrodesis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.fas.2014.02.009 | DOI Listing |
Int J Surg Case Rep
January 2025
Department of Orthopaedics and Traumatology, AZ Delta, Deltalaan 1, 8800 Roeselare, Belgium; Department of Cardio and Organ Systems, Hasselt University, Martelarenlaan 42, 3500 Hasselt, Belgium. Electronic address:
Introduction: Proximal phalanx fractures in children, especially mid-diaphyseal fractures, can result in malunion and significant functional impairment. Early malunions require prompt and effective intervention to prevent long-term complications. This case study highlights the use of intramedullary headless compression screw (IMHCS) fixation in addressing a proximal phalanx malunion.
View Article and Find Full Text PDFVet Comp Orthop Traumatol
December 2024
Surgery Department, Evidensia Dierenziekenhuis Hart van Brabant, Waalwijk, Brabant, The Netherlands.
Objective: To describe percutaneous fluoroscopy-guided placement of self-drilling, self-tapping, 3.0 mm cannulated headless compression screws (HCS) for surgical reduction of sacroiliac luxation (SIL) in cats, and to document clinical outcome.
Materials And Methods: Medical records of cats with SIL, managed by percutaneous fluoroscopy-guided placement of a 3.
J Hand Surg Glob Online
November 2024
University of Kansas Medical Center, Department of Plastic, Burn, and Wound Surgery, Kansas City, KS.
Purpose: The Evidence-Based Practice Committee of the American Society for Surgery of the Hand set out to assess the membership's practice patterns (PPs) and familiarity with evidence-based principles for scaphoid fracture and nonunion management.
Methods: Using a consensus-generated 25-item online survey, all the American Society for Surgery of the Hand members were invited to participate via email in September 2023. Two question types were used including evidence-based practice (EBP) and PPs.
Knee
December 2024
NYU Langone Health, Department of Orthopedics, Division of Sports Medicine, 333 E 38th St, New York, NY 10016, United States.
Purpose: The purpose of the current study was to define the incidence of minor and major complications following TTO at a tertiary-care institution, with determination of predictive factors related to the occurrence of a major complication.
Study Design: Retrospective case series.
Methods: Patients who underwent TTO from 2011 to 2023 were retrospectively identified.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!