Prevalence of guideline-directed medical therapy among patients receiving cardiac resynchronization therapy defibrillator implantation in the National Cardiovascular Data Registry during the years 2006 to 2008.

Am J Cardiol

Division of Cardiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado; Colorado Cardiovascular Outcomes Research (CCOR) Group, Denver, Colorado; Division of Cardiology, Veterans Administration Eastern Colorado Healthcare System, Denver, Colorado.

Published: June 2014

Cardiac resynchronization therapy (CRT) reduces morbidity and mortality among selected patients with left ventricular systolic dysfunction and severe heart failure symptoms despite guideline-directed medical therapy (GDMT). Contemporaneous guidelines provided clear recommendations regarding selection of patients for CRT, including that all patients should first receive GDMT with β blockers and renin-angiotensin axis antagonists. Prevalence of GDMT among real-world patients receiving CRT defibrillators (CRT-D) has not been well studied. We identified 45,392 patients in the National Cardiovascular Data Registry Implantable Cardioverter-Defibrillator Registry who underwent first CRT-D implantation for primary prevention of sudden death from January 2006 to June 2008. We calculated the proportion of patients with contemporaneous class I guideline indications for CRT-D, the proportion receiving GDMT for heart failure, and the proportion receiving GDMT who had class I guideline indications for CRT-D. Among patients without contraindications, 87% were prescribed β blockers, 78% an angiotensin-converting enzyme inhibitor or an angiotensin II receptor inhibitor, and 70% both a β blocker and an angiotensin-converting enzyme or angiotensin II receptor inhibitor at discharge. Finally, 50% of patients met class I guideline indications and were prescribed GDMT at discharge; 9% neither met class I indications nor were prescribed GDMT at discharge. The major limitation of this study is the lack of dosage information in the Implantable Cardioverter-Defibrillator Registry and lack of prescribing information at times other than discharge. In conclusion, many patients receiving CRT-D are not receiving GDMT at discharge. Ensuring that all patients receiving CRT-D are also receiving GDMT appears to be a quality improvement target.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4346333PMC
http://dx.doi.org/10.1016/j.amjcard.2014.03.049DOI Listing

Publication Analysis

Top Keywords

patients receiving
16
receiving gdmt
16
class guideline
12
guideline indications
12
gdmt discharge
12
patients
11
gdmt
9
guideline-directed medical
8
medical therapy
8
receiving
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!