Objective: This study was designed to assess the peak force of a manually operated chiropractic adjusting instrument, the Activator Adjusting Instrument 4 (AAI 4), with an adapter for use in animals, which has a 3- to 4-fold smaller contact surface area than the original rubber tip.

Methods: Peak force was determined by thrusting the AAI 4 with the adapter or the original rubber tip onto a load cell. First, the AAI 4 was applied perpendicularly by a doctor of chiropractic onto the load cell. Then, the AAI 4 was fixed in a rigid framework and applied to the load cell. This procedure was done to prevent any load on the load cell before the thrust impulse. In 2 situations, trials were performed with the AAI 4 at all force settings (settings I, II, III, and IV, minimum to maximum, respectively). A total of 50000 samples per second over a period of 3 seconds were collected.

Results: In 2 experimental protocols, the use of the adapter in the AAI 4 increased the peak force only with setting I. The new value was around 80% of the maximum value found for the AAI 4. Nevertheless, the peak force values of the AAI 4 with the adapter and with the original rubber tip in setting IV were similar.

Conclusion: The adapter effectively determines the maximum peak force value at force setting I of AAI 4.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmpt.2014.02.004DOI Listing

Publication Analysis

Top Keywords

peak force
24
load cell
16
adjusting instrument
12
aai adapter
12
original rubber
12
aai
9
force
8
force manually
8
manually operated
8
operated chiropractic
8

Similar Publications

The Effect of Flexible Flatfoot on the Running Function in School-Age Children.

J Orthop Res

January 2025

1-7 Gait and Motion Analysis Center, Yueyang Hospital of Integrative Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China.

Flexible flatfoot is common among school-age children and significantly affects walking efficiency, balance stability, and joint-movement coordination in children. The demands on the skeletal structure and muscle function are increased during running; however, the impact of a flexible flatfoot on children's running capabilities is unclear. In this study, we aimed to investigate the effects of flexible flatfoot on the running function of school-age children.

View Article and Find Full Text PDF

This study aimed to verify the correlations between variables obtained from dry-land tests and swimming performance, in addition to examining the associations between the dry-land asymmetries and swimming performance. Thirty-seven male swimmers performed a test battery, including shoulder isokinetic torque, shoulder range of motion (ROM), vertical jump, anthropometric, and in-water force tests. Additionally, the best official performance in the events of 50 and 200 m front crawl was obtained.

View Article and Find Full Text PDF

This study evaluates the properties of starch/chitosan films (SCF) produced via the casting method, incorporating 40 % (w/w) plasticizers (glycerol and sorbitol) and various concentrations (0, 3, 5, and 10 % (w/w)) of nanoclays (Cloisite 20A, Cloisite 30B, and K-10). The effects of each nanofiller on the films were thoroughly investigated. Films containing nanoclays exhibited reduced water solubility and enhanced thermal stability compared to films without nanofillers.

View Article and Find Full Text PDF

Muscle activity mapping by single peak localization from HDsEMG.

J Electromyogr Kinesiol

January 2025

Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden.

Human-machine interfaces using electromyography (EMG) offer promising applications in control of prosthetic limbs, rehabilitation assessment, and assistive technologies. These applications rely on advanced algorithms that decode the activation patterns of muscles contractions. This paper presents a new approach to assess and decode muscle activity by localizing the origin of individual temporal peaks in high-density surface EMG recordings from the dorsal forearm during low force finger extensions.

View Article and Find Full Text PDF

Ankle push-off is important for efficient, human-like walking, and many prosthetic devices mimic push-off using motors or elastic elements. The knee is extended throughout the stance phase and begins to buckle just before push-off, with timing being crucial. However, the exact mechanisms behind this buckling are still unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!