A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Femoral tunnel apertures on the lateral cortex in anterior cruciate ligament reconstruction: an analysis of cortical button fixation. | LitMetric

Purpose: If the aperture of the oval-shaped femoral tunnel on the lateral cortex becomes bigger than half the size of the cortical button, the risk of fixation failure increases. This study investigated the effect of the location of the entry point and diameter of the femoral tunnel on the length of the major axis of the tunnel aperture in anterior cruciate ligament (ACL) reconstruction using an outside-in technique.

Methods: Simulation of femoral tunnel drilling was performed on computed tomography (CT)-based 3-dimensional (3D) bone models obtained from 40 participants. The tunnel connected the center of the ACL footprint and various points on the lateral femoral surface. The diameter of the tunnel was set at 4.2 mm, 5.2 mm, or 6 mm, depending on the commercially available outside-in surgical systems (Arthrex, Naples, FL and Smith & Nephew, Andover, MA). The length of the major axis of the oval-shaped aperture on the lateral femoral surface was measured.

Results: When the tunnel was introduced at 2 cm from the lateral epicondyle in a 45° anteroproximal direction, the major axis was lengthened to 130.7% ± 9.0% (P < .001) of the tunnel diameter, and it was more than 6.5 mm in 65% of participants in whom a 5.2-mm-diameter tunnel was drilled. When the entry point was 3 cm from the lateral epicondyle, 60% of participants had an oval-shaped aperture with a major axis of more than 6.5 mm, even though the diameter of the tunnel was only 4.2 mm.

Conclusions: The risk of fixation failure of a cortical button increases if the entry point for drilling is 2 cm or further from the lateral epicondyle and the tunnel diameter is more than 5 mm.

Clinical Relevance: This study indicates the potential risk of cortical button fixation failure caused by an oval tunnel aperture on the lateral femoral surface in ACL reconstruction using the outside-in technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2014.03.004DOI Listing

Publication Analysis

Top Keywords

femoral tunnel
16
cortical button
16
major axis
16
tunnel
12
fixation failure
12
entry point
12
lateral femoral
12
femoral surface
12
lateral epicondyle
12
lateral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!